KRAMER: SIMPLE CREATIVE TECHNOLOGY
VP-725XLA Communication Protocol
58
Control Type Function Parameter
Description
Set
Get
0
1
123
0: Negative polarity
1: Positive polarity
Advance Output Mode: HP
0
1
124
384~2047
Advance Output Mode: VT
0
1
125
2~(HS-13)
Advance Output Mode: VW
0
1
126
15~(VT-VA-1)
Advance Output Mode: VS
0
1
127
480~1200
<= (VT-16)
Advance Output Mode: VA
0
1
128
0: Negative polarity
1: Positive polarity
Advance Output Mode: VP
0
1
129
25 < OCLK < 165
Advance Output Mode: OCLK(Integer)
0
1
130
25 < OCLK < 165
Advance Output Mode: OCLK(Decimal)
0
-
131
N/A
Advance Output Mode: Save
0
-
132
N/A
Advance Output Mode: Set Current
0
1
135
0: Follow Output
1: Follow Input
HDCP Setting
0
1
136
0: Custom1
1: Custom2
2: Custom3
3: Custom4
Advance Input Mode: Custom Input
0
1
137
0: Custom1
1: Custom2
2: Custom3
3: Custom4
Advance Output Mode: Custom Output
0
1
138
0: Off
1: On
Overscan
0
1
139
0: Seamless
1: Fast
Switching Mode
0
1
140
0: Manual
1: Auto
Auto Image Mode
0
-
141
N/A
Slideshow Start
0
-
142
N/A
Slideshow Stop
0
-
143
N/A
Slideshow Pause
0
-
144
N/A
Slideshow Next
0
-
145
N/A
Slideshow Previous
0
1
146
0: Min
1: Low
2: Mid
3: Long
4: Max
5: Off
Slideshow
0
1
147
0: 1280x768x60
1: 1366x768x60
Mode Set – Mode 3
0
1
148
0: Off
1: On
EDID Write Protect
0
1
151
0: Video Group
1: Audio Group
2: AV Group
3: Scaler
4: Master Audio
5: Master AV
Group / Master SELECT
Note :
Error when SELECT
≠ Video Group / Audio
Group / AV Group
0
1
152
0: VGA1
1: VGA2
2: VGA3
3: VGA4
Select VGA group channel
Note :
Error when SELECT
≠ Video Group / Audio
Group / AV Group
0
1
153
0: HDMI1
1: HDMI2
2: HDMI3
Select HDMI group channel
Note :