Kramer Protocol
45
45
Restart device
RESET
RESET OK
Switch to protocol 2000*
P2000
P2000 OK
* Protocol 2000 has command to switch back to ASCII protocol (like protocol 3000)
Audio parameters commands
Command
Syntax
Response
Set audio level in specific
amplifier stage.
AUD-LVL
STAGE
,
CHANNEL
,
VOLUME
Short form:
ADL
STAGE
,
CHANNEL
,
VOLUME
AUD-LVL STAGE
,
CHANNEL
,
VOLUME
RESULT
Read audio volume level
AUD-LVL?
STAGE
,
CHANNEL
Short form: ADL?
STAGE
AUD-LVL
STAGE
,
CHANNEL
,
VOLUME
Parameters Description:
STAGE
=
"In","Out"
or
Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for
Amplifier (Out) etc.
CHANNEL
= Input or Output #
VOLUME
=
Audio parameter in Kramer units, precede minus sign for negative values.
++
increase current value,
--
decrease current value.
Machine info commands
Command
Syntax
Response
* Time settings commands require admin authorization
Read in\outs count INFO-IO?
INFO-IO: IN
INPUTS_COUNT
,
OUT
OUTPUTS_COUNT
Read max presets
count
INFO-PRST?
INFO-PRST: VID
PRESET_VIDEO_COUNT
,
AUD
PRESET_AUDIO_COUNT
Reset
configuration to
factory default
FACTORY
FACTORY
RESULT
Identification commands
Command
Syntax
Response
Protocol Handshaking
#
CR
~OK
CRLF
Read device model
MODEL?
MODEL
MACHINE_MODEL
Read device serial number SN?
SN
SERIAL_NUMBER
Read device firmware
version
VERSION?
VERSION
MAJOR .MINOR .BUILD .REVISION
Set machine name
NAME
MACHINE_NAME
NAME
MACHINE_NAME
RESULT