Kramer Electronics Ltd.
VP-439
– The RS-232/Ethernet (UDP) Communication Protocol
36
HELP
Functions
Permission
Transparency
Set:
-
-
-
Get:
HELP
End User
-
Description
Syntax
Set:
-
-
Get:
Get command list or help for specific command
2 options:
1. #
HELP
␍
2. #
HELP
␠
command_name
␍
BUILD-DATE
Functions
Permission
Transparency
Set:
BUILD-DATE
End User
-
Get:
-
-
-
Description
Syntax
Set:
Read device build date
#BUILD-DATE?
␍
Get:
-
-
Response
~
nn
@
BUILD-DATE
␠
date
␠
time
␍␊
Parameters
date
–
Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time
–
Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
-
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory defaults configuration
#FACTORY
␍
Get:
-
-
Response
~
nn
@
FACTORY
␠
OK
␍␊
Notes
This command deletes all user data from the device. The deletion can take some time.
MODEL?
Functions
Permission
Transparency
Set:
-
-
-
Get:
MODEL?
End User
-
Description
Syntax
Set:
-
-
Get:
Get device model
#MODEL?
␍
Response
~
nn
@
MODEL
␠
model_name
␍␊
Parameters
model_name
– String of up to 19 printable ASCII chars