KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol 2000
16
9 Kramer Protocol 2000
The
VP-411DS
is compatible with Kramer’s Protocol
1
Note: compatible with Kramer’s Protocol 2000 does not imply that a machine includes
all of the commands below. Each machine uses a sub-set of Protocol 2000, according
to its needs.
2000 (version 0.50) (below).
This RS-232/RS-485 communication protocol uses four bytes of information as
defined below. For RS-232, a null-modem connection between the machine and
controller is used. The default data rate is 9600 baud, with no parity, 8 data bits and 1
stop bit.
Table 6: Protocol Definitions
MSB
LSB
DESTI-
NATION
INSTRUCTION
0
D
N5
N4
N3
N2
N1
N0
7
6
5
4
3
2
1
0
1st byte
INPUT
1
I6
I5
I4
I3
I2
I1
I0
7
6
5
4
3
2
1
0
2nd byte
OUTPUT
1
O6
O5
O4
O3
O2
O1
O0
7
6
5
4
3
2
1
0
3rd byte
MACHINE NUMBER
1
OVR
X
M4
M3
M2
M1
M0
7
6
5
4
3
2
1
0
4th byte
1
st
BYTE:
Bit 7 – Defined as 0.
D – “DESTINATION”:
0 - for sending information to the switchers (from the PC);
1 - for sending to the PC (from the switcher).
N5…N0 – “INSTRUCTION”
The function that is to be performed by the switcher(s) is defined by the INSTRUCTION (6 bits). Similarly, if a function is performed
via the machine’s keyboard, then these bits are set with the INSTRUCTION NO., which was performed. The instruction codes are
defined according to the table below (INSTRUCTION NO. is the value to be set for N5…N0).
2
nd
BYTE:
Bit 7 – Defined as 1.
I6…I0 – “INPUT”.
When switching (ie. instruction codes 1 and 2), the INPUT (7 bits) is set as the input number which is to be switched. Similarly, if
switching is done via the machine’s front-panel, then these bits are set with the INPUT NUMBER which was switched. For other
operations, these bits are defined according to the table.
3
rd
BYTE:
Bit 7 – Defined as 1.
O6…O0 – “OUTPUT”.
When switching (ie. instruction codes 1 and 2), the OUTPUT (7 bits) is set as the output number which is to be switched. Similarly, if
switching is done via the machine’s front-panel, then these bits are set with the OUTPUT NUMBER which was switched. For other
operations, these bits are defined according to the table.
1 You can download our user-friendly “Software for Calculating Hex Codes for Protocol 2000” from the technical support section on
our Web site at
http://www.kramerelectronics.com