Installing on a Rack 

 

7

5  Installing on a Rack 

This section describes what to do before installing on a rack and how to rack 

mount. 

 

Before Installing on a Rack 

Before installing on a rack, be sure that the environment is 

within the recommended range: 
Operating temperature range  +5 to +45 Deg. Centigrade 
Operating humidity range 

5 to 65 % RHL, non-condensing 

Storage temperature range 

-20 to +70 Deg. Centigrade 

Storage humidity range 

5 to 95% RHL, non-condensing 

 

 CAUTION!! 

When installing on a 19" rack, avoid hazards by taking 

care that: 
 
1

 

It is located within the recommended environmental 

conditions, as the operating ambient temperature of a 

closed or multi unit rack assembly may exceed the room 

ambient temperature. 

2

 

Once rack mounted, enough air will still flow around the 

machine. 

3

 

The machine is placed straight in the correct horizontal 

position. 

4

 

You do not overload the circuit(s). When connecting the 

machine to the supply circuit, overloading the circuits 

might have a detrimental effect on overcurrent 

protection and supply wiring. Refer to the appropriate 

nameplate ratings for information. For example, for fuse 

replacement, see the value printed on the product label. 

5

 

The machine is earthed (grounded) in a reliable way and 

is connected only to an electricity socket with grounding. 

Pay particular attention to supply connections other than 

direct connections to the branch circuit (for example, the 

use of power strips), and that you use only the power cord 

that is supplied with the machine.

 

 

 

 

 

 

 

 

 

 

 

How to Rack Mount 

To rack-mount the machine: 
1

 

Attach both ear brackets to the 

machine. To do so, remove the 

screws from each side of the 

machine (3 on each side), and 

replace those screws through 

the ear brackets. 

 

2

 

Place the ears of the machine 

against the rack rails, and insert 

the proper screws (not provided) 

through each of the four holes in 

the rack ears. 

Note that: 

 

In some models, the front panel 

may feature built-in rack ears

 

 Detachable rack ears can be 

removed for desktop use 

 Always mount the machine in the 

rack before you attach any cables or 

connect the machine to the power 

 If you are using a Kramer rack 

adapter kit (for a machine that is not 

19"), see the Rack Adapters user 

manual for installation instructions 

(you can download it at: 

http://www.kramerelectronics.com) 

 

Содержание VP-12NHD

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model VP 12NHD 1 12 3 UXGA CAT5 Distributor...

Страница 2: ...r VP 12NHD 1 12 3 UXGA CAT5 Distributor 8 6 1 Wiring the CAT5 LINE IN LINE OUT RJ 45 Connectors 10 7 Technical Specifications 11 Figures Figure 1 VP 12NHD 1 12 3 UXGA CAT5 Distributor 5 Figure 2 Under...

Страница 3: ...ckage includes the following items VP 12NHD 1 12 3 UXGA CAT5 Distributor Power cord This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box a...

Страница 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2...

Страница 5: ...sted pair STP cable or unshielded twisted pair UTP cable depends on the nature of the application It is recommended that in applications with high interference shielded twisted pair STP cable is used...

Страница 6: ...ing the Best Performance Achieving the best performance means Connecting only good quality connection cables thus avoiding interference deterioration in signal quality due to poor matching and elevate...

Страница 7: ...Your VP 12NHD 1 12 3 UXGA CAT5 Distributor 5 Figure 1 VP 12NHD 1 12 3 UXGA CAT5 Distributor Figure 2 Underside of the VP 12NHD 1 12 3 UXGA CAT5 Distributor...

Страница 8: ...n the polarity 2 HS Switch Slide the switch to the left 3 to invert the HS polarity 4 slide the switch to the right to NORMAL to retain the polarity 3 BLUE Trimmer Adjusts the blue level 5 4 GREEN Tri...

Страница 9: ...Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connec...

Страница 10: ...nnector on a TP 120 unit and connect the XGA OUT connector on that TP 120 unit to Display 1 OUT 2 connector to the LINE IN RJ 45 connector on a second TP 120 unit and connect the XGA OUT connector on...

Страница 11: ...Using Your VP 12NHD 1 12 3 UXGA CAT5 Distributor 9 Figure 3 Connecting the VP 12NHD 1 12 3 UXGA CAT5 Distributor...

Страница 12: ...ble with RJ 45 connectors Table 3 CAT5 PINOUT EIA TIA 568A EIA TIA 568B PIN Wire Color PIN Wire Color 1 Green White 1 Orange White 2 Green 2 Orange 3 Orange White 3 Green White 4 Blue 4 Blue 5 Blue Wh...

Страница 13: ...0 44 K FACTOR 0 05 S N RATIO 73dB CONTROLS Level 0 8dB to 2 4dB 2 switches for sync inversion COUPLING UXGA DC CAT5 AC POWER SOURCE 230 VAC 50 60 Hz 115VAC U S A 31VA DIMENSIONS 19 inch W 7 inch D 1U...

Страница 14: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Страница 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Отзывы: