Setting the DIP Switches
•
All DIP-switches are set to OFF (up) by default except for the
TP-590R
DIP-switch 1 which is set to ON
(down) by default.
•
Any changes to DIP-switches 1 and 4 require that you power cycle the device. Changes to DIP-switch 2
apply immediately.
#
Feature
Dip-switch Settings
1
Active USB Host
OFF (up)
– Host is active.
ON (down)
– Host is not active (
TP-590R
default).
2
Define IR Pass-through OFF (up)
– Pass-through the IR signal to or from the IR cable.
ON (down)
– Add IR modulation (38kHz) to the IR output signal (applies only when the IR port
is connected to an IR emitter cable).
3
N/A
For future use.
4
Programing RS-232
Off (up)
– FW programming RS-232 is inactive (Normal operation mode is enabled).
On (down)
– FW programming RS-232 is active.
Step 5: Connect power
Connect the power cord to
TP-590T
and
TP-590R
plug it into the mains electricity.