Kramer TP-46N Скачать руководство пользователя страница 8

 

TP-46N - Overview

 

 

 

The Power Connect feature where the 

TP-46N

 can power the 

TP-45

 or 

TP-45RC

 over the same CAT 5 cable (see 

Section 

 3.1

 

EQ. and LEVEL controls 

 

A CAT 5 output for transmitting the signal to an additional receiver 

 

12V DC power 

3.1 

About the Power Connect Feature 

The Power Connect feature applies as long as the cable can carry power. This 

feature is available when using STP cable and the distance does not exceed 50m 

(164ft) on standard CAT 5 cable. For longer distances, heavy gauge cable should 

be used (CAT 5 cable is still suitable for the video/audio transmission, but not for 

feeding the power at these distances).

 

For units which are connected via RJ-45 

connectors, make sure that the shield of the STP cable is connected to the metal 

casing of the connectors on both ends of the cable. For units which are connected 

via terminal block connectors, the shield of the STP cable must be connected to a 

ground terminal on the units at both ends (use the ground terminal of the power 

supply connection if necessary). 

For a CAT 5 cable exceeding a distance of 50m, separate power supplies should 

be connected to the transmitter and to the receiver simultaneously.

 

3.2 

Shielded Twisted Pair (STP)/Unshielded Twisted Pair 
(UTP) 

We recommend that you use Shielded Twisted Pair (STP) cable, and stress that 

the compliance to electromagnetic interference was tested using STP cable. There 

are different levels of STP cable available, and we advise you to use the best 

quality STP cable that you can afford.

 

Our non-skew-free cable, Kramer

 BC-STP

 

is intended for analog signals where skewing is not an issue. 

In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew-free 

cable, Kramer 

BC-XTP

, may be advantageous, and UTP cable might also be 

preferable for long range applications. In any event when using UTP cable, it is 

advisable to ensure that the cable is installed far away from electric cables, motors 

and so on, which are prone to create electrical interference. 

Содержание TP-46N

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL TP 46N Component UXGA Audio Receiver P N 2900 300027 Rev 3...

Страница 2: ......

Страница 3: ...ted Pair UTP 5 3 3 Defining the TP 46N 6 4 Connecting a Component UXGA Audio Distribution System 7 4 1 Connecting the System in UXGA Mode 8 4 2 Connecting the System in Component Video Mode 10 4 3 Wir...

Страница 4: ...UP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROU...

Страница 5: ...terference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tigh...

Страница 6: ...cted and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recov...

Страница 7: ...or TP 45RC receives a UXGA and audio signal and transmits it over the CAT 5 cable to the UXGA output on the TP 46N receiver If component video is selected the component video signal is transmitted ov...

Страница 8: ...cable must be connected to a ground terminal on the units at both ends use the ground terminal of the power supply connection if necessary For a CAT 5 cable exceeding a distance of 50m separate power...

Страница 9: ...appropriate level 7 EQ Trimmer Adjusts the cable compensation equalization level Use a screwdriver to carefully rotate the trimmer adjusting the appropriate level 8 LINK LED Lights when receiving the...

Страница 10: ...be configured to operate in one of two audio modes In the analog mode an analog audio source is connected to the input and transmitted to an acceptor connected to the receiver see Section 4 1 In the...

Страница 11: ...cables is on our Web site at http www kramerelectronics com 2 On the TP 45 use the SELECT buttons as follows Press the video SELECT button to choose the UXGA input Press the audio SELECT button to ch...

Страница 12: ...to the mains electricity on both the TP 45 and the TP 46N not shown in Figure 2 The signal from the UXGA source is transmitted via CAT 5 cable decoded and converted at the UXGA OUT 15 pin HD F connec...

Страница 13: ...ELECT button to choose S PDIF Release the audio SELECT button to choose analog audio 3 On the TP 45RC use the SELECT buttons as follows Momentarily press the VIDEO SELECT button The UXGA LED turns off...

Страница 14: ...ideo and outputted on the Y CB PB CR PR OUTPUTS RCA connectors to the component video acceptor If you cannot connect the power to both the TP 45 and TP 46N connect it to the TP 46N only If more than o...

Страница 15: ...pinout using a straight pin to pin cable with RJ 45 connectors Note that the cable ground shielding must be connected soldered to the connector shield EIA TIA 568B Figure 4 CAT 5 PINOUT PIN Wire Color...

Страница 16: ...S 1 stereo analog audio 0dBu 1k 0 5V 75 on a 3 5mm jack 1 digital S PDIF audio on an RCA connector MAX AUDIO INPUT LEVEL ANALOG 4dBu on 50k AC coupling MAX AUDIO OUTPUT LEVEL ANALOG 4dBu on 1k DC coup...

Страница 17: ......

Страница 18: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300027 Rev 3 SAFETY...

Отзывы: