![Kramer SummitView SV-552 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/kramer/summitview-sv-552/summitview-sv-552_user-manual_2000820012.webp)
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Defining the SV-552 Processor/Switcher
8
Table 2: SV-552 SummitView
™
Processor/Switcher Underside Features
#
Feature
Function
1
POWER
LED
Lights when the unit receives power
2
AUTO
LED
Lights when the unit is configured to automatically identify and
select an input according to a preconfigured priority
3
LOCK
LED
Lights when the front panel buttons are locked
4
VIDEO 1
INPUTS
Buttons
(used for testing)
Press to select the video 1 source
VIDEO 2
Press to select the video 2 source
5
PC 1
Press to select the PC 1 source
PC 2
Press to select the PC 2 source
PC 3
Press to select the PC 3 source
6
HDMI
Press to select the HDMI source
7
PROGRAM
USB Connector
Program software - for service use only
8
MONITOR OUT
Terminal Block
Connect to an external audio amplifier. This is the same as the
audio Line Out but lacks level control
9
LINE OUT
Terminal Block
Connect to an external audio amplifier. This is the same as the
Monitor Out but with level control
10
SPKR
Terminal Block
Connect to the left and right speakers
11
PHANTOM
DIP-switch 1
AUX IN
Configures Aux In for use with a microphone
MIC
DIP-switch 2
Turns on Phantom Power 9V on the Aux In connector
12
L, G, R
Terminal Block
Connect to an additional audio source or microphone for mixing
with the audio line level input (talk over)
13
IR IN
3.5mm Mini Connector
Connect to an IR receiver
14
OUTPUTS TO PROJECTOR DVI
Connector
Connect to the DVI/HDMI input of the projector
15
PC 1
INPUTS
RJ-45 Connectors
Connect to the PC 1 source
PC 2
Connect to the PC 2 source
PC 3
Connect to the PC 3 source
16
ETHERNET
RJ-45 Connector
Connect to a PC running the Site-CNTL software via the network or
Internet for control and configuration of the unit. Default IP settings:
Address 192.168.1.39, port 50000, subnet mask 255.255.255.0
17
K-NET
1
Terminal Block
Connect pin G to the Ground connection; Connect pin B and pin A to
the RS-485, and pin +12V to the power adapter. For details on
connecting K-Net, see
Figure 10
18
TERM
DIP-switches
DIP-switches for line termination of the unit (DIP-switch 1 is for
K-Net, DIP-switch 2 is for RS-485)
19
PROJECTOR
RS-232
9-pin D-sub
Connector
Connect to the projector for projector control
20
MUTE
Terminal Block
Mutes the audio outputs
21
10V VOL
Terminal Block
Connect to an external potentiometer on a wall plate
2
to adjust the
volume of the speakers
22
RELAYS
Terminal Block
Connect to a room item (such as lighting, screen settings, blinds, and
so on)
23
RS-232
Terminal Block
Connect to the RS-232 connector on any serial controlled device
1 K-Net is a proprietary Kramer protocol for interconnecting Kramer units
2 For example, the RC-63DL