![Kramer SP-10D Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/kramer/sp-10d/sp-10d_user-manual_2000816019.webp)
Communication Protocol
17
Byte 2 Command Description
Byte 3 (parameter value)
GLOBAL
20
OUTPUT FORMAT
0 - YUV
1 - RGB
2 - RGBS
21
OUTPUT_STANDARD
0 - PAL B
1 - PAL N
2 - PAL M
3 - NT 3
4 - NT 4
5 - SEC
22
GENLOCK
0 - OFF
1 - ON
23
PANEL_LOCK
0 - OFF
1 – ON
24
SCH
-100 - +100
24
DELAY
-100 - +100
26
FREEZE
0 - OFF
1 - ON
27
PROGRAM
0 - 15 (read only)
28 GENLOCK_STAT
(Read
only)
0 – No GENLOCK
1 – GENLOCK
Byte 4 is the machine address: can be 98 or 99 (in HEX).
First byte = I
Second byte=D
Third byte=E
MACHINE TO PC:
MACHINE
POWER-UP
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)
PRESS
OF
"RECALL"
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)
PRESS
OF
"STORE"
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)
CHANGE
"OUTPUT_STANDARD"
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)
CHANGING
OTHER
KEYS
PC <- I = 33;D = PARAMETER NUMBER; E = PARAMETER <- MACHINE (PARAMETER WRITE)
PC TO MACHINE:
RESET
VIDEO
POWER-UP(PSEUDO)
PC -> I = 0;D = 0;E = 0 -> MACHINE
PC <- I = 0;D = 0;E = 0 <- MACHINE
DEFAULT
PC -> I = 0;D = 1;E = 0 -> MACHINE
WRITE EEPROM ALL PARAMETERS - DEFAULT (ALL PROGRAMS),RELOAD (RESTART)
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)
PARAMETER
READ
PC -> I = 32;D = PARAMETER NUMBER;E = 0 -> MACHINE
PC <- I = 32;D = PARAMETER NUMBER;E = PARAMETER <- PARAMETER
PARAMETER
WRITE
PC -> I = 33;D = PARAMETER NUMBER;E = PARAMETER -> MACHINE
PC -< I = 33;D = PARAMETER NUMBER;E = PARAMETER <- MACHINE
WRITE
OUTPUT_STANDARD
PC -> I = 33;D = 21;E = PARAMETER -> MACHINE MACHINE RELOAD (RESTART)
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)
RECALL
PC -> I = 34;D = 0;E = PROGRAMM NUMBER -> MACHINE
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE
PROGRAMM NUMBER - 0 = PROGRAMM 1
PROGRAMM NUMBER - 1 = PROGRAMM 2
PROGRAMM NUMBER - 15 = PROGRAMM 16