SID-X1 - Connecting the SID-X1
9
9
To connect a remote step-in switch and LED as illustrated in the
example in
Figure 4
:
1. Connect pins 2 and 3 from the terminal block to the remote step-in switch.
2. Connect pin 1 from the terminal block to the anode of the remote step-in
LED.
3. Connect pin 3 from the terminal block to the cathode of the remote step-in
LED.
5.2
Connecting the Remote Select Switch and LED
You can connect a remote, contact closure, input selection switch to activate an
input (momentary contact is sufficient to switch inputs), as well as an indicator
LED to the terminal block on the rear panel of the
SID-X1
.
Figure 5
illustrates the connections from the terminal block to the switch and LED.
Figure 5: REMOTE SELECT Switch and LED Wiring
To connect a remote selection switch and LED as illustrated in the
example in
Figure 5
:
1. Connect pins 2 and 3 from the terminal block to the remote selection switch.
2. Connect pin 1 from the terminal block to the anode of the remote selection
LED.
3. Connect pin 3 from the terminal block to the cathode of the remote selection
LED.