Performing a Phase Calibration
In the event that there is noise visible on the picture, you should perform a phase
calibration.
To perform a phase calibration:
1. Press the Step-In button to ensure that the SID-VGA is the active input.
The Step-In button lights.
2. Press and hold the Step-In button.
The phase calibration pattern is displayed.
3. Release the Step-In button as soon as the noise disappears.
Technical specifications
Technical specifications of the
SID-VGA
Table 2: Technical specifications
1
of the SID-VGA UXGA Step-In Commander
INPUTS:
Video: 1 VGA (up to UXGA) on a 15-pin HD (F) connector
Audio: 1 unbalanced stereo audio on a 3.5mm mini jack
OUTPUT:
TP on an RJ-45 Ethernet connector
STEP-IN COMMANDER
DISTANCE:
50m (164ft) up to 1080p @60Hz
POWER CONSUMPTION:
12V DC, 380mA
OPERATING
TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
–40° to +70°C (–40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
DIMENSIONS:
12cm x 7cm x 2.4cm (4.7" x 2.76" x 0.94”) W, D, H
WEIGHT:
0.3kg (0.66lbs) approx
ACCESSORIES:
Power supply
1 Product details are subject to change without notice
SID-VGA
UXGA Step-In Commander
Installation Instructions
For the latest information on our products and a list of Kramer distributors,
P/N:
2900- 000712
Rev:
4
Kramer Electronics, Ltd.
P/N: 2900-000712 REV 4
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203