Kramer RC-76R Скачать руководство пользователя страница 5

 

RC-76R/RC-78R - Getting Started 

 

Getting Started 

We recommend that you: 

 

Unpack the equipment carefully and save the original box and packaging 

materials for possible future shipment 

 

Review the contents of this user manual 

 

Use Kramer high performance high resolution cables  

 

 

 

Go t

http://www.kramerelectronics.com

 to check for up-to-date 

user manuals, application programs, and to check if firmware 

upgrades are available (where appropriate). 

2.1 

Achieving the Best Performance 

To achieve the best performance: 

 

Use only good quality connection cables to avoid interference, deterioration 

in signal quality due to poor matching, and elevated noise levels (often 

associated with low quality cables) 

 

Do not secure the cables in tight bundles or roll the slack into tight coils 

 

Avoid interference from neighboring electrical appliances that may adversely 

influence signal quality  

 

Position your Kramer 

RC-76R/RC-78R 

away from moisture, excessive 

sunlight and dust 

 

 

 

This equipment is to be used only inside a building. It may only be 

connected to other equipment that is installed inside a building. 

 
 
 
 
 
 
 
 

i

!

Содержание RC-76R

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL RC 76R RC 78R Room Controllers P N 2900 300253 Rev 2...

Страница 2: ......

Страница 3: ...e K NET Port 10 4 5 Grounding the RC 76R RC 78R 10 5 Operating the RC 76R RC 78R 12 6 Front Panel Button Caps and Labels 13 6 1 Installing the Front Panel Button Caps and Labels 16 7 Technical Specifi...

Страница 4: ...roups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeate...

Страница 5: ...chieving the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise leve...

Страница 6: ...nt WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Elect...

Страница 7: ...t soft k config 1 general purpose I O port that can be configured by K Config as a digital input digital output or analog input for interfacing with a variety of devices such as sensors switches LEDs...

Страница 8: ...ial controller through computer LAN to control AV products 4 IR 2 Terminal Block Connector Connect to IR emitter cable 2 5 IR 1 Terminal Block Connector Connect to IR emitter cable 1 6 RELAY C2 Connec...

Страница 9: ...ller 14 Program Switch Slide the switch to the left when programming the unit slide to the right for normal operation 15 RS 485 Terminal Block Connector Pins B and A are for RS 485 Pin G may be connec...

Страница 10: ...R outputs as follows Connect an IR emitter to IR OUTPUT 1 and attach the emitter to the DVD player 1 Connect an IR emitter to IR OUTPUT 2 and attach the emitter to the DVD player 2 2 Connect the RS 23...

Страница 11: ...them to the RC 76R RC 78R via their RS 232 connection To connect a device to the RC 76R RC 78R via RS 232 Using a straight cable connect pin 2 to TX pin 3 to RX and pin 5 to GND on the RS 232 termina...

Страница 12: ...ort The Ethernet connection of the RC 76R RC 78R lets you perform all control functions of the RC 76R RC 78R over the Internet using a PC running the Kramer Site CTRL control program to control AV dev...

Страница 13: ...ation switch up otherwise make sure it is set to down see Figure 1 4 5 Grounding the RC 76R RC 78R The grounding screw is used to earth the chassis of the unit to the building ground preventing static...

Страница 14: ...point wire a green yellow AWG 18 0 82mm2 wire crimped with a proper hand tool is recommended 2 Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above...

Страница 15: ...the K Config software For instructions on using the software see the K Config Software Guide available from our Web site www kramerelectronics com A PC running Site CTRL control software To operate y...

Страница 16: ...Panel Button Caps and Labels 13 6 Front Panel Button Caps and Labels The RC 76R RC 78R are supplied with a button label sheet and 6 8 clear button caps to house the labels Figure 5 illustrates a sampl...

Страница 17: ...14 RC 76R RC 78R Front Panel Button Caps and Labels...

Страница 18: ...RC 76R RC 78R Front Panel Button Caps and Labels 15 Figure 5 Sample Button Label Sheet...

Страница 19: ...ecora front plate from the device Put the plate and screws aside 3 To access the buttons remove the two button cover plate mounting screws see Figure 6 and remove the button cover plate Put the plate...

Страница 20: ...Retaining the orientation return each cap to its correct button Figure 8 Replacing the Button Cap 7 Repeat for all caps 8 Replace the button cover plate and screw it into place with its mounting screw...

Страница 21: ...ectors DEFAULT IP SETTINGS IP number 192 168 1 39 Mask 255 255 0 0 Gateway 0 0 0 0 POWER CONSUMPTION 12V DC 260mA OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F...

Страница 22: ......

Страница 23: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300253 Rev 2 SAFETY...

Отзывы: