K-CONFIG –
Using the Triggers
117
Figure 217: GPI/O Events – GPI/O Trigger Properties
2.
Select the GPI/O port from the list and its function behavior:
Figure 218: GPI/O Events – Digital Input: Selecting the GPI/O Port and Behavior
3.
Select the condition for activating the trigger.
For Digital Input mode:
Behavior
Action
Pullup
Trigger Condition Description
Level moved from High to
Low
Activates the trigger
immediately
checked
Closing the circuit
not checked voltage exceeding its maximum defined
value
Level Moved from Low to
High
Activates the trigger
immediately
checked
Opening the circuit
not checked voltage decreasing below its minimum
defined value
Level is High for:
The trigger is activated on the
first occurrence
checked
Circuit remains open
not checked The voltage exceeding its maximum defined
value and staying there for a set period of
time (see
Level is Low for:
The trigger is activated after the
defined timeout expires
checked
Circuit remains closed
not checked The voltage decreasing below its minimum
defined value and staying there for a set
period of time (see
Figure 219: GPI/O Events – Setting the Digital Input Condition Timeout
For Analog Inputs
Behavior
Action
Value is lower than
Activates the trigger once the voltage is below the set voltage
Value is Higher
Activates the trigger once the voltage is above the set voltage