Kramer Electronics Ltd.
FC-404NETxl
– Connecting FC-404NETxl
7
For any microphone that needs +48 volts of power, see
Connecting Balanced Inputs
When using a balanced input source and connector, you must ensure that the hot, cold, and
ground pins of the connector are matched up to the +,
–, and ground pins of the
FC-
404NETxl
terminal block connector respectively. The following diagrams illustrate how to
connect a standard XLR and 6.5mm phone jack.
Figure 4: Connecting a Balanced XLR Input
Figure 5: Connecting a Balanced 6.5mm Phone Jack
Connecting Unbalanced Inputs
When using an unbalanced input source, a jumper must be added between the negative (
–)
and ground terminals. The unbalanced source is connected to the positive (+) and ground
terminals.
Note
: A jumper is required for connecting an unbalanced input.
Figure 6: Connecting an Unbalanced RCA Input
Figure 7: Connecting an Unbalanced 6.5mm Phone Jack