Command -
TIME-SRV
Command Type - System
Command Name
Permission
Transparency
Set:
TIME-SRV
End User
Public
Get:
TIME-SRV?
End User
Public
Description
Syntax
Set:
Set time synchronization from
server
#
TIME-SRV
␠
mode, srv_ip, sync_hour
␍
Get:
Get time synchronization settings
#
TIME-SRV?
␍
Response
For Set: ~nn@
TIME-SRV
␠
mode,srv_ip,sync_hour
␍␊
For Get: ~nn@
TIME-SRV
␠
mode,srv_ip,server_status,sync_hour
␍␊
Parameters
Mode -
0 - disabled, 1 - enabled
srv_ip
- time server IP address
sync_hour
- hour in day for time sync
server_status - ON/OFF
Response triggers
Notes
Device must have a valid gateway (NTGT command) and DNS server (NTDNS command)