background image

 

FC-202NET - Introduction

 

 

Introduction 

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been 

providing a world of unique, creative, and affordable solutions to the vast range of 

problems that confront the video, audio, presentation, and broadcasting 

professional on a daily basis. In recent years, we have redesigned and upgraded 

most of our line, making the best even better! 

Our 1,000-plus different models now appear in 14 groups that are clearly defined 

by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix 

Switchers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; 

GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; 

GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; 

GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters and 

GROUP 11: Sierra Products; GROUP 12: Digital Signage; and GROUP 13: Audio, 

and GROUP 14: Collaboration. 

Congratulations on purchasing your Kramer 

FC-202NET 

2 x 2 Dante Interface

which is ideal for the following typical applications: 

 

Boardrooms 

 

Classrooms 

 

Hospitality 

 

Transportation 

 

Retail 

 

Entertainment 

 

Houses of worship 

 
 

Содержание FC-202NET

Страница 1: ...KRAMER ELECTRONICS LTD PRELIMINARY USER MANUAL MODEL FC 202NET 2 x 2 Dante Interface P N 2900 300405 Rev 1 ...

Страница 2: ......

Страница 3: ...ng the FC 202NET 6 5 2 Connecting the Inputs 7 5 3 Connecting the Outputs 9 6 Setting the DIP switch 10 7 Troubleshooting 11 8 Technical Specifications 12 Figures Figure 1 FC 202NET 2 x 2 Dante Interface Rear Panel 5 Figure 2 Connecting the FC 202NET 2 x 2 Dante Interface 6 Figure 3 Connecting a Balanced XLR Input 8 Figure 4 Connecting a Balanced 6 5mm Phone Jack 8 Figure 5 Connecting an unbalance...

Страница 4: ...ined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products GROUP 12 Digital Signage...

Страница 5: ...rference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer FC 202NET away from moisture excessive sunlight and dust This equipment...

Страница 6: ...llected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at http www kra...

Страница 7: ...als that can output 50W of audio into 70V or 100V speaker systems The FC 202NET 2 x 2 Dante Interface features A Dante network interface Two balanced line level mic inputs Two balanced line level outputs from the network Independent gain setting per channel Independent phantom power setting per channel 1 4U Rack housing ...

Страница 8: ...Ethernet Connector Connect to the Dante audio source via the LAN 3 OUTPUT 6 pin Terminal Block 2 Connect to the second balanced line level audio acceptor G 4 1 Connect to the first balanced line level audio acceptor G 5 INPUT 6 pin Terminal Block 2 Connect to the second balanced line level audio source G 6 1 Connect to the first balanced line level audio source G 7 8 way DIP switch Sets the phanto...

Страница 9: ...on 5 1 Connecting the inputs see Section 5 2 Connecting the outputs see Section 5 3 5 1 Connecting the FC 202NET Always switch off the power to each device before connecting it to your FC 202NET After connecting your FC 202NET connect its power and then switch on the power to each device Figure 2 Connecting the FC 202NET 2 x 2 Dante Interface i ...

Страница 10: ... example an amplified speaker 6 Connect the power adapter to the FC 202NET and plug the power adapter into the mains power supply 5 2 Connecting the Inputs Your FC 202NET is provided with a 3 pin terminal block for each input channel This connector can accept either a balanced or an unbalanced connection however some modifications must be made for an unbalanced connection See the next two sections...

Страница 11: ...e Jack 5 2 2 Connecting Unbalanced Inputs When using an unbalanced input source a jumper must be added between the negative and ground terminals The unbalanced source is connected to the positive and ground terminals Note A jumper is required for connecting an unbalanced input Figure 5 Connecting an unbalanced RCA Input ...

Страница 12: ...g the Outputs Your FC 202NET is provided with a 3 pin terminal block for each output channel This connector offers a balanced output to interface with the input of another device Connection methods for balanced and unbalanced outputs are identical as the methods for inputs as referenced in Section 5 2 ...

Страница 13: ...phantom power to each channel according to the DIP switch settings shown in the following table DIP switch Number Channel Function Switch Setting State 1 2 2 Gain On On Low gain Off Off High gain 3 4 Phantom Power On On Power on Off Off Power off 5 6 1 Gain On On Low gain Off Off High gain 7 8 Phantom Power On On Power on Off Off Power off ...

Страница 14: ...or is lit Check that Dante has been configured properly The input is not sent to another network device or the sound is distorted Check that Dante has been configured properly Check that the inputs are properly configured If the input source requires pre amplification or phantom power see Section 6 ...

Страница 15: ...GAIN 0dB nominal FREQUENCY RESPONSE 100Hz 0dB to 20kHz 3dB SYSTEM THD 0 05 at any gain input signal 3dB below maximum OUTPUT SIGNAL to NOISE RATIO 0dB 1Vpp 1kHz 0 06 MAXIMUM OUTPUT LEVEL 3 6dBu POWER CONSUMPTION 5V DC 1 1A CLASS D OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing COOLING Convection vents ENCLOSURE TYPE Alumi...

Страница 16: ......

Страница 17: ...isit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect the unit from the power supply before opening and servicing P N 2900 300405 Rev 1 ...

Отзывы: