FC-132ETH - Configuring and Maintaining the FC-132ETH
33
10
Configuring and Maintaining the FC-132ETH
This section describes:
Terminating the RS-485 bus (see
Selecting the RS-232/RS-485 Port (see
Activating and deactivating DHCP (see
Resetting to the factory default settings (see
Upgrading the firmware (see
10.1
Terminating the RS-485 Bus
The devices at both ends of the RS-485 chain must be terminated; all other devices
in the chain must be left unterminated.
To terminate the RS-485 bus
:
Slide the RS-485 Term switch down
10.2
Selecting the RS-232 or RS-485 Port
The 3-pin Serial terminal block can be used as either an RS-232 or as an RS-485
port.
To set the Serial port as an RS-232 port:
Release the RS-232/RS-485 button on the rear panel.
The Serial RS-232 LED lights and selection is shown on the display
To set the Serial port as an RS-485 port:
Depress the RS-232/RS-485 button on the rear panel.
The Serial RS-485 LED lights and the selection is shown on the display
10.3
Activating and Deactivating DHCP
The IP address of the
FC-132ETH
can be set either statically or dynamically where
it is issued by a DHCP server.