13 DATA (G, Rx, Tx)Terminal Block
Connectors
Connect to a serial data source (for example, a room controller) or to an acceptor for
tunneling control commands via HDBaseT.
14 Remote 5-pin Terminal Block
Connector
Connect to contact closure switches (by momentary contact between the desired pin and
G pin).
INPUT
– Short press—toggles between the PC, DP++ and HDMI inputs; Long press—
adjusts the VGA phase shift.
STEP-IN
– activate the STEP-IN function.
VOL UP, VOL DOWN
– Short press—increases/decreases the volume by one step;
Long press
—Increases/decreases the volume from 0% to 100%/100% to 10% in 10
seconds.
15 FACTORY RESET Button
Short press
– Power cycle (reboot) the device.
Long press
– Reset IP settings to factory default values.
16 SETUP 4-way DIP-switches
Set the device behavior.
17 PROG Mini USB Port
Connect to a PC to perform firmware upgrade.
18 HDBT OUT RJ-45 Connector
Connect to an HDBaseT receiver (for example,
TP-780Rxr
,
TP-588D
or
TP-580Rxr
) and
provide or accept power (bidirectional PoE).
19 LINK LED
Lights green when there is a valid HDBT link.
20 48V DC Power Terminal Block
Connector
Connect to the Kramer power adapter.
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.
Step 3: Mount DIP-22
Install
DIP-22
using one of the following methods:
•
Attach the rubber feet and place the unit on a flat surface.
•
Fasten a bracket (included) on each side of the unit and attach it to a flat surface
www.kramerav.com/downloads/DIP-22
•
Mount the unit in a rack using the recommended rack adapter
www.kramerav.com/product/DIP-22
•
Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•
Avoid uneven mechanical loading.
•
Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•
Reliable earthing of rack-mounted equipment should be maintained.
•
Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your
DIP-22
.
To achieve specified extension distances, use the recommended Kramer cables available at
www.kramerav.com/product/DIP-22
Using third-party cables may cause damage!
Step 5: Connect power
Connect the power cord to
DIP-22
and plug it into the mains electricity.
Safety Instructions (See
for updated safety information)
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.