Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your
TP-580RA
.
SETUP DIP-switches
A DIP-switch that is down is on, up is off (by default, DIP-switch 3 is set to ON
and all the other DIP-switches are set to OFF). Changes to DIP-switches 7 and
8 only take effect after power-cycling the device. Changes to DIP-switches 1
and 3 only take effect after unplugging and then replugging the input cable.
#
Function
Status
1
EDID lock
Off (up)
– EDID parameters are passed-through.
On (down)
– EDID Locked. When EDID is locked, the audio parameters are set as defined by
DIP-switch 3. In the pass-through mode, DIP-switch 3 setup is ignored.
2
Extracted audio
Off (up)
– HDBT IN source audio is selected for extraction.
On (down)
– HDMI OUT ARC sink audio is selected for extraction.
3
Audio pass-through
Off (up)
– Passes the audio parameters.
On (down)
– Limits the audio to 2-channel LPCM.
This setup is enabled after unlocking and relocking the EDID by setting DIP-switch 1 to On (EDID locked).
4
HDCP operation
Off (up)
– Passes HDCP.
In this state, if the sink supports HDCP, the input declares HDCP support. It will then handle HDCP on the
output and input actively. If the sink does not support HDCP then the input will declare HDCP is not supported.
On (down)
– HDCP off.
In this state, the device does not support HDCP on its input, even if HDCP is detected on the output.
5
Color space
Off (up)
– Color space parameters are passed-through.
On (down)
– Forces RGB color space.
6
RS-232 mode
Off (up)
– RS-232 control of device; RS-232 extension mode is disabled.
On (down)
– RS-232 extension mode.
7
HDBT FW upgrade
Off (up)
– Normal operation mode.
On (down)
– HDBT FW upgrade mode, device normal operation is disabled.
This setup is enabled only after DIP-switch 6 is set to On (RS-232 extension mode).
8
CPU FW upgrade
Off (up)
– Normal operation mode.
On (down)
– CPU FW upgrade mode, device normal operation is disabled; DIP-switch 6 is set to Off.
To achieve specified extension distances, use the recommended Kramer cables available at
www.kramerav.com/product/TP-580RA
Using third-party cables may cause damage!
Step 5: Connect power
Connect the power cord to
TP-580RA
and plug it into the mains electricity.
Safety Instructions (See
for updated safety information)
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.
•
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
•
To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.