Step 6: Operate 676T and 676R
Set the 676T DIP-switches
The DIP-switch setup on
676T
applies to all the
676R
devices that are connected.
A DIP-switch that is down is on, up is off. Changes to the DIP-switches take effect immediately. By-default, all DIP-switches
are set to Off
#
Function
Status
1
EDID Lock
Off (up)
– Unlock stored EDID.
On (down)
– Lock stored EDID.
2
Color Depth
Off (up)
– Follow output color depth.
On (down)
– Force 8-bit color depth.
3
Input HDCP Appearance
Off (up)
– HDCP ON. Always input HDCP-supported appearance.
On (down)
– HDCP OFF. Always input HDCP-unsupported appearance (MAC
mode).
4
For future use
Control the devices
Operate remotely, by RS-232 serial
commands transmitted by a touch
screen system, PC, or other serial
controller
RS-232 Control / Protocol 3000 on the Micro USB
Baud Rate:
115,200
Parity:
None
Data Bits:
8
Command Format:
ASCII
Stop Bits:
1
Example (get device model name): #model?<cr>
Factory Default Parameters
Reset front panel
button:
Press and hold for over 5 seconds to reset the device to
factory default settings.
P3K command:
#factory<cr>