Wireless Full Bin Alarm 

Installation and Operating Manual 
Series 6 

 

The Wireless Full Bin Alarm is designed 
to provide the ultimate in convenience 
and safety to perform tasks remotely. 
It is a radio frequency (RF) sensing 
device that helps prevent overfilling of 
grain bins by activating an alarm when 
the grain Sensor Probe is activated. 
The Sensor Probe, which operates at 

915.8

 

MHz FM, transmits securely encoded information to the Receiver, which 

then decodes the information and alerts the user that the bin is full. The Sensor 
Probe and Receiver are designed to operate within 300' but actual range is 
dependent on operating environment. 

Содержание 40006

Страница 1: ...ng device that helps prevent overfilling of grain bins by activating an alarm when the grain Sensor Probe is activated The Sensor Probe which operates at 915 8 MHz FM transmits securely encoded information to the Receiver which then decodes the information and alerts the user that the bin is full The Sensor Probe and Receiver are designed to operate within 300 but actual range is dependent on oper...

Страница 2: ...fit or costs of removal installation or reinstallation Table of Contents Specifications 1 FCC 2 Industry Canada 2 Overview 3 Mechanical Installation 4 Receiver Console 4 Sensor Probe 4 Electrical Installation 4 Receiver Console 4 Sensor Probe 5 General Operation 5 Receiver Console 5 Sensor Probe 7 Sensor Self Test 8 Sensor Angle Setup 8 Limited Warranty 9 Table of Figures Figure 1 Full Bin Alarm 3...

Страница 3: ...cations Sensor Power 9 Volt DC Battery Frequency 915 8 MHz Modulation FM Frequency Modulation Indicators Internal System Battery Test Case Size 3 dia x 13 long Range 300 depending on environment Security Code Preprogrammed Unique Identifier Environment Weatherproof Receiver Power in 12 VDC Standby Current 40mA Alarm Current 200mA Case Size 8 x 4 8 x 2 5 Power Input 15 16ga 2 conductor wire with pl...

Страница 4: ... which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry C...

Страница 5: ...d monitoring system that indicates when the grain level in the bin is reaching its maximum The system consists of a Receiver Console with audible and visible alarms a Sensor Probe that hangs into the grain bin suspended from the spout of an auger The battery powered Sensor Probe is fully sealed and communicates wirelessly via radio frequency RF to the Receiver Console When the grain level becomes ...

Страница 6: ...own in the following figure Use a quick link to attach the chain to the U bolt and the second quick link to attach the chain to the Sensor Probe The U bolt may be mounted on the inside of the spout if space is limited Figure 2 U Bolt Instructions Electrical Installation Receiver Console Connect 12VDC and ground to the Power Input wires as marked The polarity must be as follows 12V on the white wir...

Страница 7: ...ical it transmits an alarm signal which causes the Yellow receive LED to light and the alarm to activate The alarm signal is both an array of LED lights and audible beeper acting simultaneously The Receiver Console activates the alarm when the alarm signal is received The alarm remains on for ten seconds or until the Cancel button is pressed If the Sensor Probe remains activated the alarm will con...

Страница 8: ...a signal from the transmitter to be learned Tilt the probe to send a signal and the receiver will read the probe s security code and store it in memory The Receive LEARN light will flash three times to indicate that the transmitter has been successfully learned and the Receive LEARN light will turn off and receiver will then enter normal operating mode Up to eight probes can be learned by a receiv...

Страница 9: ...rm signal periodically This is indicated by a blink of the yellow receive LED on the console If the Sensor Probe remains tilted greater than the threshold angle for more than one minute transmission will cease and the Sensor Probe will return to low power sleep mode Only when the Sensor Probe is returned to the vertical position will it resume normal operation Sensor Self Test To test the battery ...

Страница 10: ...by unthreading the top from the bottom 2 Slide the Angle Program Switch shown below in its rightward position to the leftward position 3 Find a flat surface parallel to the ground and then stand the probe straight up This will be the zero angle reference 4 Press and hold do not release the white self test button until the yellow LED illuminates This stores the zero angle in the probe 5 Tilt the se...

Страница 11: ...rt of a product of the company s manufacture which proves to be defective in normal use and service during this time Labor to install or repair such parts will be absorbed by Kramble Industries Inc If this work is to be done other than Kramble personnel prior approval must be given by Kramble Industries Inc as to rate and time This warranty shall bind the company only as follows 1 The warranty sha...