Krais P&P K50-1250 Скачать руководство пользователя страница 4

TASKS SHOULD BE PERFORMED IN SUCH A

MANNER THAT THE WRISTS ARE MAIN-

TAINED IN A NEUTRAL POSITION WHICH IS

NOT FLEXED, HYPEREXTENDED, OR TURNED

SIDE TO SIDE.

STRESSFUL POSTURES SHOULD BE AVOID-

ED AND CAN BE CONTROLLED THROUGH

TOOL SELECTION AND WORK LOCATION.

Any user suffering from prolonged symptoms of

tingling, numbness, blanching of the fingers, clum-

siness or weakened grip, nocturnal pain in the

hand, or any other disorder of the shoulders, arms,

wrists, or fingers is advised to consult with a physi-

cian. If it is determined that the symptoms are job

related or aggravated by movements and pos-

tures dictated by the job design, it may be neces-

sary for the employer to take steps to prevent fur-

ther occurrences. These steps might include, but

are not limited to, repositioning the work piece or

redesigning the workstation, reassigning workers

to other jobs, rotating jobs, altering awork pace,

and/or changing the type of tool used so as to min-

imize stress on the operator. Some tasks may

require more than one type of tool to obtain the

optimum operator/tool/task relationship.

The following recommendations will help reduce or

moderate the effects of repetitive work motions:

uses a minimum handgrip force consistent with

proper control and safe operation;

keep wrists as straight as possible;

keep body and hands warm and dry.

Avoid anything that inhibits blood circulation

smoking tobacco;

cold temperatures;

certain drugs.

PAGE 4

Safety Recommendations - cont.

Avoid highly repetitive movements of the hands

and wrists, and continuous vibration exposure.

Use of this tool may produce hazardous fumes,

particles, and/or dust. To avoid adverse health

effects utilize adequate ventilation and/or a respira-

tor. Read the material safety data sheet of any

materials involved in the tube expansion process.

This KRAIS product is designed to operate on min-

imum 90 psig (6.2 bar), maximum 125 psig (8.6)

air pressure. If the tool is properly sized and

applied, higher air pressure is unnecessary.

Excessive air pressure increases the loads and

stresses on the tool parts, mandrels, rolls and

cages and may result in premature wear and or

breakage. Installation of a filter-regulator-lubricator

in the air supply line ahead of the tool is required.

Before the tool is connected to the air supply,

check the throttle for proper operation (i.e., the

throttle moves freely and returns to the closed

"OFF" position when released). Clear the air hose of

accumulated dust and moisture. Be careful not to

endanger adjacent personnel. Before removing a

tool from service or changing sockets, make sure

the airline is shut off and drained of air. This will pre-

vent the tool from operating if the throttle is acci-

dentally engaged.

It is essential for safe operation that any operator of

OUR TOOLS uses good balance, sure footing, and

proper posture in anticipation of a torque reaction.

Ensure that the operator's hands will not be

wedged or pinched between the work and the tool

when operating.

NOTE: ANY USE OF THIS TOOL OTHER

THAN IT'S INTENDED PURPOSE COULD

CAUSE MAJOR DAMAGE TO THE TOOL AS

WELL AS POSE A RISK TO THE OPERATOR. 

Содержание P&P K50-1250

Страница 1: ...READ SAFETY RECOMMENDATIONS BEFORE USE THIS TOOL MANUAL INSTRUCTION Model P P K50 400 P P K50 600 P P K50 1250...

Страница 2: ...l Lwa 94 dBa 94 dBa 94 dBa Weight 4 76 kg 4 76 kg 4 76 kg 10 5 Lbs 10 5 Lbs 10 5 Lbs Length 311 mm 311 mm 311 mm 12 1 4 12 1 4 12 1 4 Side To Center Distance 1 7 16 36 5mm 1 7 16 36 5mm 1 7 16 36 5mm...

Страница 3: ...erator must then resist the stall torque until the throttle is released Higher torque pneumatic tools inline and right angle are supplied with a torque reaction bar designed to work with the torque of...

Страница 4: ...ndations cont Avoid highly repetitive movements of the hands and wrists and continuous vibration exposure Use of this tool may produce hazardous fumes particles and or dust To avoid adverse health eff...

Страница 5: ...off trip as follows Remove two screws 80 holding valve cover 79 in place Remove cover to expose trip During forward rotation the trip abuts valve 5A See page 10 for trip adjustment illustration WARNI...

Страница 6: ...forward rather than in reverse causing over rolling of joints It is therefore essential that the outer valve be free in the bushing After the above checks have been made rein stall the valve cover Ens...

Страница 7: ...1 K 850 44 1 55 OPERS TING CAM K 900 49 1 K 900 49 1 K 900 49 1 56 RETAINER K 1000 52 1 K 1000 52 1 K 1000 52 1 57 BALL RETAINER K 900 52 1 K 900 52 1 K 900 52 1 58 GUIDE SPRING K 900 47 3 K 900 47 3...

Страница 8: ...PAGE 8 Push Pull K50 1250...

Страница 9: ...PAGE 9 Push Pull K50 600...

Страница 10: ...PAGE 10 Push Pull K50 400...

Страница 11: ...tting valve plunger See Diagram The above adjustment allows the valve to shut off at the mid point of the total trip movement of the tool Model K50 Trip Adjustment We recommend that this adjustment be...

Страница 12: ...set up These tubes should measure as calculated within the allowable tolerance Condenser tubes 10 to 17 ga 3 4mm to 1 5mm 0 001 0 025mm Condenser tubes 18 to 24 ga 1 25mm to 0 5mm 0 0005 0 012mm Boil...

Страница 13: ...Cl le ea ar ra an nc ce e c h b Tube ID measure d W Wa al ll l t th hi ic ck kn ne es ss s w b d 5 5 w wa al ll l r re ed du uc ct ti io on n f 0 05 x w F Fi in ni is sh he ed d I I D D g c d f STEP T...

Страница 14: ...BE Example 1 2 3 4 S 1 Tube Sheet Hole 760 19 3 mm 2 Tube O D 750 19 05 mm 3 Clearance 010 2 54 mm 4 Tube I D 620 15 74 mm 5 Wall Thickness TOT 130 3 3 mm 6 5 Wall Reduction 006 0 152 mm 7 Finished I...

Страница 15: ...inst defects in material and work manship For warranty evaluation contact your local supplier Tools returned for war ranty evaluation have to be shipped prepaid to your nearest distributor or our comp...

Страница 16: ...Przedsi biorstwo Produkcyjno Remontowe KRAIS Poland 55 106 Zawonia Czachowo 15 tel 48 71 312 05 96 fax 48 71 387 03 32 http www krais pl email expanders krais pl...

Отзывы: