6.3 Electrical connection
ATTENTION
The power supply line must match the used preamplifier.
Electrical data
Number of measuring channels
2
Operating voltage
U
B
= 11 - 30 V DC
Reverse-polarity protection
Impulse amplitude
U
A
≥ 0.8
UB
Impulse shape with symmetrical output
signal
Rectangular , Pulse duty factor /
Channel 1:1 ±15 %
Impuls offset between the two channels
90° ± 30°
± 30 mA
Stand-
ard
45 mA
max-
imum
150 mA
Frequency
Overview nominal sizes
Protection class
IP 65 (DIN EN 60529)
Signal output
Push-Pull
TIPP
Shielded cable, LIYCY C-grey 4 x 0.25 mm²
ATTENTION
Damage by overvoltage
Excessive voltage can cause damage and dysfunction to the product.
a) Use the product only with the correct voltage.
b) Please consult the manufacturer in cases of doubt.