KPS KPS-PF740 Скачать руководство пользователя страница 2

Leakage clamp meter

ENGLISH

ENG

ENG

See the full

instruction manual:

Safety Information

WARNING

Please particularly note that inappropriate use may cause shock or damage to the meter. 

When using the meter, comply with common safety procedures and completely follow the 

safety measures in this operation manual.

To make full use of the meter’s functions and ensure safe operation, please carefully read 

and follow the procedures in the operation manual.

The  meter  is  designed  and  manufactured  according  to  safety  requirements  of  

EN  61010-1:2010,  EN  61010-2-032,  EN  61010-2-033  on  electronic  measuring  instrument 

and hand held digital multipurpose meter. And conforms to UL STD 61010-1, 61010-2-032,  

61010-2-033,  Certified to  CSA  STD.C22.2  NO.  61010-1,  IEC  STD  61010-2-032,  

IEC  STD  61010-2-033.  The  product  meets  with  the  requirements  of  600V  CAT  III  

and pollution degree 2.

All safety guidelines outlined should be followed otherwise the protection provided by the 

instrument may be impaired.

Warning symbols in the manual alert users of potential dangerous situations.

Precautions are to prevent the user from damaging the instrument or the test object.

Preparation

•  When using the meter, the user should comply with standard safety rules: 

 - General shock protection

 - Prevent misusing the meter 

•  After  receiving  the  meter,  please  check  for  damage  that  may  have  occurred  during

transportation. 

•  lf the meter is stored and shipped under hard conditions, please confirm that the meter 

is undamaged.

•   Probe should be in good condition. Before use, please check whether the probe insulation 

is damaged, whether metal wire is bare. 

•  Use the probe table provided with the meter to ensure safety. lf necessary, replace the

probe with another identical probe or one with the same specification

Usage

•  When using the meter, select the right function and measuring range. 

•  Don’t measure when exceeding the maximum value in each measuring range. 

•  When measuring a circuit with the meter connected, do not touch the probe tip (metal

part). 

•  When measuring, if the voltage to be measured is more than 60 V DC or 30 V AC (RMS), 

always keep your fingers behind the finger protection device

•  Do not measure voltage greater than AC 600V.

•  In the manual measuring range, when the value to be measured is not known in advance, 

choose the highest measuring range to begin, and then gradually select lower ranges until 

the correct range is identified.

•  Before rotating conversion switch to change measuring function, remove probe from the

circuit to be measured. 

•  Don’t measure resistors, capacitors, diodes and circuits that are energized. 

•  During the test of current, resistors, capacitors, diodes and circuit connections, do not

allow the meter to connect with voltage source.

•  Don’ t measure capacitance unless the capacitor is discharged completely.

•  Don’ t use the meter in explosive gas, vapor or dusty environments.

•  If you find any abnormal condition or failure on the met er, stop using the meter and have 

it serviced by a qualified technician

•  Unless  the  meter  bottom  case  and  the  battery  cover  are  completely  fastened  in  their

original places, do not use the met er.

•  Don’ t store or use the meter in direct sunlight, high temperature or high humidity.

Maintenance

•  Don’ t try to open the meter bottom case to adjust or repair. Such operations only can be

made by qualified technicians who fully understand the meter and electrical shock hazard.

•  Before opening the meter bottom case or battery cover, remove probe from the circuit to

be measured.

•  To  avoid  wrong  readings  and  potential  electric  shock,  when 

  appears  on  the  meter

display, replace the battery immediately.

•  Clean the meter with damp cloth and mild detergent . Do not use abrasives or solvents.

•  Power off the meter when it i s not used. Switch the transfer switch to OFF position

•  If the meter is not used for long time, please take the battery out to prevent the meter

being damaged.

Replace Battery

WARNING

To avoid electric shock, make sure that the test leads have been clearly move away from 

the circuit under measurement before opening the battery cover of the meter.

WARNING

Do  not  mix  old  and  new  batteries.  Do  not  mix  alkaline,  standard  (carbon-  zinc),  or 

rechargeable (ni-cad, ni-mh, etc) batteries.

•  If the sign

 appears, it means that the batteries should be replaced.

•  Loosen the fixing screw of the battery cover and remove it

•  Replace the exhausted batteries with new ones.

•  Put the battery cover back and fix it again to its origin form

Note:

Do not reverse the polarity of the batteri s.

Replacing Test Leads

Replace test leads if leads become damaged or worn.

WARNING

Use meet EN 61010-031 standard, rated CAT III 600V, or better test leads.

Accessories

•  Test leads

1 pair

•  Summary instruction manual

1 pc.

•  1.5V AAA battery

3 pcs.

•  K-type thermocouple

1 pc.

ENGLISH

MGL EUMAN,

 S.L.

 

Parque Empresarial de Argame,

 

C/Picu Castiellu, Parcelas i-1 a i-

E-33163 Argame, Morcí

n

Asturias, España, (Spain)

APAC: 

MGL GLOBAL SOLUTIONS LTD

[email protected]

Flat 4-1, 4/F, No. 35, Section 3 Minquan 

East Road. Taipei, Taiwan.

Tel: +886 2-2508-0877

EMEA: 

MGL EUMAN S.L.

[email protected]

Parque Empresarial Argame, 33163 

Morcín. Asturias, Spain.

Tel: +34 985-08-18-70

AMERICAS: 

MGL AMERICA, LLC.

[email protected]  

US East Coast:

 2810 Coliseum Centre 

Drive, Ste. 100. Charlotte, North Carolina, 

28217 USA

Tel: +1 833 533-5899

US West Coast:

 760 Challenger Street. 

Brea, California 92821 USA

Tel: +1 310-728-6220

www.mgl-intl.com

Отзывы: