12
KPS-MA10 • Isolation, voltage and continuity meter
2000Ω and repeat the test.
NOTE: do not connect the device to voltages higher than 500 VAC rms.
5. SPECIFICATIONS
Insulation resistance
Measuring Scales:
200MΩ, testing voltages: 250V, 500V DC +/-
10%
Resolution: 1 account/100KΩ
Measuring Scale:
2000MΩ, testing voltage: 1000V DC +/- 10%
Resolution: 1 account/1MΩ
Precision:
+/-1,5% of r/-5 digits (200MΩ scale)
+/-3% of r/-3 digits (below 1 GΩ)
+/-5% of r/-5 digits (below 2 GΩ)Output
current::
1 mA DC min. 0.25 MΩ (250V scale)
1 mA DC min. 0.5 MΩ (500V scale)
1 mA DC min. 1 MΩ (1,000V scale)
Energy Consumption:
Max. Current Consumption approx. 250mA
AC voltage
Scale:
0-500V
Resolution: 1V
Precision:
+/- 1,5% of r/- 3 digits
Line Frequency
Interval:
40-120Hz
Continuity
Ohm Scale::
0-20Ω
Resolution:
0,01Ω
Precision:
+/-1.5% of r/-5 digits
Terminal voltage
Open circuit:
4 V DC min.
Terminal current
Open circuit:
210 mA DC min.
Ohm Scale:
0-2 KΩ
Resolution:
1Ω
Precision:
+/- 1,5% of r/-3 digits