3
Burner(s) does not light after ODS/pi-
lot is lit.
1. Burner orifice is clogged.
2. Burner orifice diameter is too small.
3. Inlet gas pressure is too low.
1. Clean burner orifice (see
Care and
Maintenance
page ) or replace
burner orifice.
2. Replace burner orifice.
3. Contact local natural or propane/LP
gas company.
Delayed ignition of burner(s).
. Manifold pressure is too low.
2. Burner orifice is clogged.
. Contact local natural or propane/LP
gas company.
. Clean burner (see
Care and Main-
tenance
page ) or replace burner
orifice.
Burner backfiring during combustion. 1. Burner orifice is clogged or dam
-
aged.
. Burner damaged.
3. Gas regulator defective.
1. Clean burner orifice (see
Care and
Maintenance
page ) or replace
Burner orifice.
. Replace burner.
3. Replace gas regulator.
Slight smoke or odor during initial
operation.
. Residues from manufactory.
. Not enough combustion/ventila-
tion air.
. Problem will stop after a few hours.
. Refer to air for combustion and venti-
lation requirements.
. Control knob not fully pressed in.
. Control knob not pressed in long
enough.
3. Equipment shutoff valve not fully
open.
4. Thermocouple connection loose at
control valve.
5. Pilot flame not touching thermocou
-
ple, which allows thermocouple. This
problem could be caused by one or
both of the following:
a) Low gas pressure.
b) Dirty or partially clogged ODS/pilot
6. Control valve damaged.
. Pressed in control knob fully.
. After ODS/pilot lights, keep control
knob pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, and then
tighten /4 turn more.
5.
a) Contact local natural or propane/ LP
gas company.
b) Clean ODS/pilot (see
Care and Mai
tenance
page ), or replace ODS/pilot
assembly.
6. Replace control valve.
When ignitor button is pressed in,
there is a spark at ODS/pilot but no
ignition.
PROBLEM
POSSIBLE CAUSE
REMEDY
Содержание GLD1850