8
SPECIFICATIONS
2.0 SPECIFICATIONS
2.1 Appliance Components
Part Number
Description
SL60-160
Control Board Assembly
SL60-135
Burner Assembly
SL60-SLK
Light Kit
700-203
Manual Gas Shut-off Valve
SL60-057T
Glass Frame Assembly
SL42-028
Fan Kit (2)-75 CFM
700-508
Remote Control
SL36-085
5 in (127 mm) Restrictor Plate
SL60-HHS
Vent Heat Shield Assembly
2.1.1 Additional Components Required
• Refer to Section 8.0 Venting on page 26, for approved vent
systems.
• Refer to Section 9.3 Glass Media Installation on page 32
for glass media options (various colors available, see your
dealer for details).
2.2 Heating Specifications
Natural Gas
LP Gas
Maximum
Input Rating
55,000 Btu/h
(16.12 kW)
55,000 Btu/h
(16.12 kW)
Minimum
Input Rating
17,500 Btu/h
(5.13 kW)
17,500 Btu/h
(5.13 kW)
Manifold Pressure
(High)
3.8” WC
(0.95 kPa)
11” WC
(2.74 kPa)
Manifold Pressure
(Low)
1.1” WC
(0.27 kPa)
2.9” WC
(.72 kPa)
Orifice Size
(DMS)
CENTER BURNER: 33
SIDE BURNERS: 51
CENTER BURNER: 52
SIDE BURNERS: 59
2.2.1 Altitude Adjustment
This appliance may be installed at higher altitudes. Please refer
to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1
Natural Gas and Propane Installation Code, local authorities,
or codes having jurisdiction in you area regarding derate
guidelines.
2.2.1.1 US Installations
Refer to the American Gas Association guidelines for the gas
designed appliances derating method. For elevations above 2,000
ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft
(305 m) above sea level.
2.2.1.2 Canadian Installations
When the appliance is installed at elevations above 4,500 ft (1,372
m), the certified high altitude rating shall be reduced at the rate of
4% for each additional 1,000 ft (305 m). Hannah Hussong