D.  Convert Gas Control Valve

Step 1:  With a T20 Torx (star-bit) driver, remove (2) screws from the 

regulator solenoid assembly. See 

FIGURE 3.

Step 2:  Remove and discard the old stepper regulator solenoid 

assembly and gasket from valve body.

Step 3:  Remove the protective plastic cover on the included stepper 

regulator solenoid assembly.

Step 4:  Install new gasket into the gasket groove and place stepper 

regulator solenoid assembly on to the valve.

Step 5:  Secure the assembly to the gas valve with (2) screws previously 

removed. DO NOT OVERTIGHTEN! 

Step 6:  Connect the new stepper regulator solenoid assembly gang 

plug into the control module as shown in  

Step 7:  Slide the fuel type selector to NG. See 

FIGURE 4

.

E.  Complete the Conversion

Step 1:  Adjust the front and back burner venturis. Loosen the screw 

securing the venturi cap and adjust to the correct setting. See 

FIGURE 5

 

and 

TABLE 2.

Regardless of venturi orientation, closing the air shutter will 

achieve a desired yellow flame, but may produce soot on the 

glass. Opening the air shutter will cause a short, blue flame that 

may lift off the burner.
Slight adjustments to the venturi opening will create dramatic 

results. Adjust at slight increments until desired look is achieved.

Step 2:  Reinstall all components previously removed in section 

A

 (pg. 

3). Refer to the installation manual for more information.

Step 3:  Turn the manual valve counterclockwise to the ON position. 
Step 4:  Reconnect electrical power.
Step 5:  Check for leaks at all connections with soapy water.

Table 2, Factory Set Venturi Openings

Fuel

Front venturi opening

Back venturi opening

Natural Gas

1/8” (3mm) OPEN

1/8” (13mm) OPEN

Remove Torx screws

Propane/Natural Gas Switch

(Fuel Setting)

Flame Modulation/

Stepper Motor Connection

Front venturi

Back venturi

FIGURE 3, 

Torx Screws Securing Stepper Regulator Solenoid Assembly

FIGURE 4, 

Control Module

FIGURE 5, 

Burner Venturis

Содержание NCK-C39-D

Страница 1: ...THE APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with the appliance Please read the appliance owner s man...

Страница 2: ......

Страница 3: ...and burner heat shield Refer to the installation manual for more information B Replace Burner Orifices Step 1 Remove the existing front and back orifice caps See FIGURE 1 Step 2 Replace with the orif...

Страница 4: ...enturi cap and adjust to the correct setting See FIGURE 5 and TABLE 2 Regardless of venturi orientation closing the air shutter will achieve a desired yellow flame but may produce soot on the glass Op...

Страница 5: ...utlet pressure tap screw clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to the outlet pressure tap to verify tap is completely...

Страница 6: ...consulter le manuel d installation B Remplacement des orifices de br leurs tape 1 Retirez les orifices des br leurs avant et arri re Voir FIGURE 1 tape 2 Remplacez les par les orifices fournis avec c...

Страница 7: ...ustez le au r glage appropri Voir FIGURE 5 et TABLEAU 2 tape 2 R duire l ouverture de l obturateur d air du venturi avant ou arri re donnera la couleur de flamme jaune d sir e mais cela peut encrasser...