DIRECT WIRE INSTALLATION:
NOTE: The cord must be removed and wiring disassembled.
Insert 115 V wiring (with ground) through the romex connector and
wire to the speed control / receptacle assembly, matching the black,
white & green (ground) wires to the corresponding wires on the speed
control / receptacle assembly.
MODEL #CSK-335-RF ONLY: FAN INSTALLATION INSTRUCTIONS
I
NSTALLATION OF THIS FAN WIRING SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
IMPORTANT: A fan assembly is pre-installed and wired to the RF gas valve in the CSK-335-RF models. A receptacle
and 8 ft. fan cord have been installed, wired and mounted in a removable electrical access panel on the right
side of the fireplace. If wiring to the pre-installed electrical box is desired, the wiring should be run prior to
permanently setting the fireplace in place and connecting the vent system. A direct wire connection to the
electrical box provided must be performed by qualified electrician.
NOTE:
If this insert is being installed in the minimum opening dimensions, the wiring may need to be
completed after the fireplace insert is set in place.
The fan is equipped with a three-prong (grounding) plug attached to the end of the fan electrical cord for protection against
shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not remove the
grounding prong from the plug. Do not allow any excess fan cord to touch the fireplace.
NOTE:
Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer to your
local electrical codes for specific requirements in your area.
WARNING:
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong
from this plug.
Figure D-2
1. Remove the (2) screws securing the removable access panel (with electrical box & romex connector installed) from the
right side of the fireplace.
2. Insert 115V wiring (with ground) through the romex connector and wire to the duplex receptacle. Secure the duplex
receptacle to the electrical box.
3. Place the cover on the electrical box and secure with screw.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Codes, CSA C22.1.
Содержание CSK-335
Страница 33: ...Page 31 ...
Страница 34: ...Page 32 ...