background image

OPERATING INSTRUCTIONS 

25

WARNING

Do not operate appliance with the glass front removed, cracked, 
or broken. Replacement of the glass should be done by a licensed 
or qualiied service person.

Under no circumstances should any solid fuel (wood, coal, paper, 
cardboard, etc.) be used in this appliance.

Children and adults should be alerted to the hazards of high 
surface temperature and should stay away to avoid burns or 
clothing ignition.

CAUTION

Clothing or other lammable material should not be placed on or 
near the appliance.

Young children should be carefully supervised when they are in the 
same room as the appliance. Toddlers, young children and others 
may be susceptible to accidental contact burns. A physical barrier 
is recommended if there are at risk individuals in the house. To 
restrict access to a ireplace or stove, install an adjustable safety 
gate to keep toddler, young children and other at risk individuals 
out of the room and away from hot surfaces.

WARNING: 

If you do not follow these instructions exactly, a ire or explosion may result causing property damage, 

personal injury, or loss of life.

1. 

STOP! Read all the safety information above on this page. 

2. 

Press the wireless remote OFF button. 

3. 

Turn of all electric power to the appliance. 

4. 

This appliance is equipped with an ignition device which 
automatically lights the pilot. Do not try to light the pilot by 
hand.

5. 

Locate the manual valve installed by your qualiied service 
technician.

6. 

Turn the manual valve clockwise 

to the OFF position. 

7. 

Wait ive (5) minutes to clear out any gas. Then, smell 
for gas, including near the loor. If you smell gas, STOP! 
Follow ‘B’ in the safety information above. If you do not smell 
gas, go to the next step. 

8. 

Turn the manual valve counterclockwise  

to the ON 

position. 

9. 

Turn on all electric power to the appliance. 

10. 

Press the wireless remote ON button. 

11. 

If the appliance will not operate, follow the instructions, “To 
Turn Of Gas To Appliance” and call your service technician 
or gas supplier. 

OPERATING INSTRUCTIONS

NOTE

When this ireplace is initially lit, condensation will appear on the glass. This is normal in all gas ireplaces and will disappear after 
several minutes. A paint smell will occur during the irst few hours of burning. It is recommended to leave the fan of during this period to 
help speed the paint curing process. This ireplace may produce noises of varying degree as it heats and cools due to metal expansion 
and contraction. This is normal, and does not afect the performance or longevity of the ireplace.

A. 

This appliance is equipped with an ignition device which 
automatically lights the pilot. Do not try to light the pilot by 
hand. 

B. 

BEFORE OPERATING

 smell around the appliance area for 

gas. Be sure to smell next to the loor because some gas is 
heavier than air and will settle on the loor. 

WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not use any phone 

in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the ire 

department. 

C. 

Use only your hand to turn the gas control manual valve. 
Never use tools. If the valve will not turn by hand, do not 
try to repair it; call a qualiied service technician. Force or 
attempted repair may result in a ire or explosion. 

D. 

Do not use this appliance if any part has been under water. 
Immediately call a qualiied service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control that has been under water. 

ON/OFF 

ON

OFF

1. 

Press the wireless remote OFF button.

2. 

Turn of all electric power to the appliance if service is to 
be performed. 

3. 

Locate the manual valve installed by your qualiied service 
technician.

4. 

Turn the manual valve clockwise 

to OFF position. 

FOR YOUR SAFETY READ BEFORE OPERATING

TO TURN OFF GAS TO APPLIANCE

11.0  OPERATING INSTRUCTIONS

Содержание CHASKA 29-ROCK CSK-29-R

Страница 1: ...e not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certiied kit is us...

Страница 2: ......

Страница 3: ...omer safety We offer our continual support and guidance to help you achieve the maximum beneit and enjoyment from your Kozy Heat gas ireplace Jim Hussong President Dudley Hussong Board Chairman Homeow...

Страница 4: ......

Страница 5: ...CONNECTION 18 7 1 Gas Conversion sold separately 18 7 2 Gas Line Installation 18 8 0 FACING AND FINISHING 19 8 1 Clearances to Combustibles 19 8 2 Shroud Installation 20 8 3 Safety Barrier Installati...

Страница 6: ......

Страница 7: ...accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certiied 1 2 3 Signage A metal or plastic identiication plate shall be permanently mounted to the ext...

Страница 8: ...ivent Metal Fab Selkirk Simpson Dura Vent and ICC TM IVT cap only 2 2 Heating Specifications Natural Gas LP Gas Maximum Input Rating 30 500 Btu h 9 0 kW 30 000 Btu h 8 8 kW Minimum Input Rating 16 000...

Страница 9: ...Vent Center Back to Vent Center Inches 19 1 4 29 18 7 8 14 1 2 14 1 8 7 3 16 8 7 8 5 5 8 Millimeters 488 737 479 368 360 183 225 143 14 368mm 187 8 479mm 87 8 225mm 2 51mm 73 16 183mm 29 737mm 29 750...

Страница 10: ...h this appliance may result in property damage or personal injury A B C D E F G H Figure 2 2 Proper Positioning of CSK 29 L Exploded View Table 2 2 Field Assembled Parts A Fireplace insert F Fan kit B...

Страница 11: ...rier shall be replaced with Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used Please refer to Section 8 3 Safety Barrier Installation on page 20 for insta...

Страница 12: ...ace insert is removed 3 2 1 Existing Fireplace Opening Minimum Requirements See Figure 3 1 A Height 194 in 489 mm B Front Width 29 in 749 mm C Depth 15 in 381 mm D Back Width 188 in 479 mm 3 2 2 Exist...

Страница 13: ...ARNING This appliance must not share or be connected to a chimney flue serving any other appliance Approved vent caps require 12 in 305mm clearance to intersecting walls overhangs or eaves as veriied...

Страница 14: ...18 If the factory built ireplace has no gas access hole s provided an access hole of 1 in 37 5 mm or less may be drilled through the lower sides or bottom of the irebox in a proper workmanship like ma...

Страница 15: ...r on the right side NOTE The exhaust pipe will have a red marking IMPORTANT Maximum horizontal vent runs of 24 in 609 mm require a 1 in 25mm rise per 12 in 305 mm run 1 Carefully extend the exhaust an...

Страница 16: ...mney place unfaced insulation around the irst 3 ft 914 mm of vent system below termination cap Secure with wire 2 Install the 3 x 3 lexible pipes down through existing chimney Guide ropes if used to a...

Страница 17: ...ce 1 Slide the gas ireplace insert into existing ireplace opening until the channels on top of the appliance are aligned with the air duct 2 Insert the air duct pull rod handle through access slot at...

Страница 18: ...ply piping system by closing its individual manual shut off valve A listed and Commonwealth of Massachusetts approved in 13 mm tee handle manual shut of valve and lexible gas connector are to be conne...

Страница 19: ...G 19 8 0 FACING AND FINISHING 8 1 Clearances to Combustibles 12 305mm 10 254mm 37 946mm 35 895mm 16 407mm 45 COMBUSTIBLE MANTEL COMBUSTIBLE MATERIAL 6 152mm CLEARANCE TO ADJACENT SIDEWALL Figure 8 1 M...

Страница 20: ...holes on the shroud to the corresponding mounting nuts on the sides of the insert metal cabinet 5 Secure with 4 truss head screws provided 6 Reinstall all components previously removed Figure 8 2 Uppe...

Страница 21: ...Disconnect all electrical power from the fireplace before performing this task ATTENTION If converting to LP propane gas complete the conversion before installing any light kit components Follow the...

Страница 22: ...for potential adjustments in rock placement and usage Hussong Manufacturing suggests removing 4 R7 rocks and 2 R11 rocks Reference the following illustrations for proper rock placement Do not block pi...

Страница 23: ...10 screws securing control board Remove the control board 9 4 2 Control Board Installation 1 Place the control board in irebox aligning the holes in board with mounting studs at the bottom of the ireb...

Страница 24: ...cut or remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local c...

Страница 25: ...the appliance will not operate follow the instructions To Turn Of Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this ireplace is initially lit con...

Страница 26: ...position for remote control operation of the main burner and ireplace features 11 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Страница 27: ...y 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After approximat...

Страница 28: ...option The standing pilot will keep the irebox warm and establish a draft in the vent which allows the main burner to ignite with less air low disruption When the system is OFF the LCD screen will di...

Страница 29: ...t to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and set te...

Страница 30: ...s will operate at previous setting There is no delay in start up or stop time 11 8 9 Accent Light Kit Optional The light intensity can be adjusted through 6 levels 1 Press the mode key to index to th...

Страница 31: ...maximum recommended pressure settings 4 Turn of burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight...

Страница 32: ...r Table 12 3 Factory Set Venturi Openings Fuel Air Shutter Opening Natural Gas 1 8 3 mm OPEN LP Gas 5 8 15 mm OPEN 12 2 1 1 Venturi Adjustment NOTE If soot is present on the glass check rock positioni...

Страница 33: ...ane gas in tank Check LP propane tank Reill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a low line...

Страница 34: ...ri Adjustment on page 32 Incorrect vent cap installation Adjust if necessary Vent cap blockage Remove debris if necessary Flame burns blue and lifts off burner Improper venturi setting Venturi air shu...

Страница 35: ...fans from electrical current and vacuum The bearings are sealed and require no oiling 14 2 Vent System NOTE If the vent air intake system is disassembled for any reason reinstall per instructions prov...

Страница 36: ...Oriice 53 700 253 Pilot Assembly LPG 700 551 1 Conversion Kit NG NCK CK29L S Transmitter Remote Control 700 408 Conversion Kit LPG LCK CK29L S Pilot Oriice NG 700 094 Burner Assembly CK29L 135 GLASS...

Страница 37: ...ssong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole oblig...

Страница 38: ......

Страница 39: ...e defective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective irep...