Horizontal Terminations (cont.)
SECTION 7
VENTING
#CLW-50-MV
R.1 October 2021
49
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
7.6.2 Horizontal Terminations (cont.)
Natural Gas and Propane Installations
IMPORTANT: Horizontal vent sections require 1/4” (6mm) of rise for
every 12” (305mm) of travel.
vent configurations are shown with rigid pipe. Listed vent
systems
with flexible pipe can be installed
following the vent manufacturer’s installation instructions.
(i)
Minimum Vertical / Minimum Horizontal
45° vertical elbow + 90° horizontal elbow + 6” (152mm) minimum
horizontal run + termination cap
(i)
Minimum Vertical / Maximum Horizontal
45° vertical elbow + 90° horizontal elbow + 48” (1219mm)
maximum horizontal run + termination cap
(ii)
Minimum 12” Vertical Vent Pipe / Minimum Horizontal
45° vertical elbow + 12” (305mm) vertical vent pipe + 90°
horizontal elbow + 6” (152mm) minimum horizontal run +
termination cap
(ii)
Minimum 12” Vertical Vent Pipe / Maximum Horizontal
45° vertical elbow + 12” (305mm) vertical vent pipe + 90°
horizontal elbow + 12’ (3.6m) maximum horizontal run +
termination cap
(iii)
Minimum 24” Vertical Vent Pipe / Minimum Horizontal
45° vertical elbow + 24” (610mm) vertical vent pipe + 90°
horizontal elbow + 6” (152mm) minimum horizontal run +
termination cap
(iii)
Minimum 24” Vertical Vent / Maximum Horizontal
45° vertical elbow + 24” (610mm) vertical vent pipe + 90°
horizontal elbow + 20’ (7.32m) maximum horizontal run +
termination cap
(iv)
BASEMENT INSTALL - Minimum Vertical / Minimum Horizontal
45° vertical elbow + 24” (610mm) minimum 5” x 8” vertical
4” x 6-5/8” r 90° horizontal 4” x 6-5/8” elbow +
6” (152mm) minimum horizontal run + termination cap
(iv)
BASEMENT INSTALL - Minimum Vertical / Maximum Horizontal
45° vertical elbow + 24” (610mm) minimum 5” x 8” vertical
4” x 6-5/8” r 90° horizontal 4” x 6-5/8” elbow +
4’ (1219mm) maximum hori termination cap
6”
(152mm)
48”
(1219mm)
24” (610mm) vent pipe
6”
(152mm)
48”
(1219mm)
A
B
D
A
B
D
C
i
6”
(152mm)
12’
(3.66m)
12” (305mm) vent pipe
A
B
D
ii
6”
(152mm)
24” (610mm) vent pipe
20’
(7.32m)
A
B
D
iii
iv
DIAG. 3
NATURAL GAS & PROPANE HORIZONTAL TERMINATIONS
(A)
45° Elbow
(B)
90° Elbow
(C)
Reducer
(D)
Termination Cap