VENTING
23
7.1.3 Install Exhaust and Combustion Air
Intake Collars to Fireplace Rear
7.1.4 Install Cover Plates to Fireplace Top
WARNING: The cover plates must be installed on the top of the
fireplace. DO NOT proceed with the fireplace installation until
the vent conversion is completed.
1
2
3
1
2
3
INSTALL 4” (101mm) EXHAUST COLLAR TO
APPLIANCE REAR. VERIFY GASKET IS IN PLACE.
SECURE WITH (6) SCREWS PREVIOUSLY REMOVED.
INSTALL 6⅝” (168mm) COMBUSTION AIR INTAKE COLLAR
TO APPLIANCE REAR. VERIFY GASKET IS IN PLACE.
SECURE WITH (4) SCREWS PREVIOUSLY REMOVED.
INSERT TABS ON REAR COVER PLATE INTO
SLOTS AT THE REAR. SECURE WITH (1)
SCREW PREVIOUSLY REMOVED.
INSTALL EXHAUST COVER PLATE TO
APPLIANCE TOP. VERIFY GASKET IS IN PLACE.
SECURE WITH (6) SCREWS PREVIOUSLY REMOVED.
INSTALL COMBUSTION AIR INTAKE COVER PLATE TO
APPLIANCE TOP. VERIFY GASKET IS IN PLACE.
SECURE WITH (4) SCREWS PREVIOUSLY REMOVED.
INSERT TABS ON OUTER COVER PLATE INTO
SLOTS ON APPLIANCE TOP. SECURE WITH (1)
SCREW PREVIOUSLY REMOVED.