#BAY-41-MV R.1 July 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
LIGHTING INSTRUCTIONS
51
10.1 Flame Height and Heat
Output Adjustment
This fireplace is equipped with a manual HI/LO pressure modulator
knob, located on the gas valve, for adjusting main burner flame
height and the heat output of the fireplace.
•
Remove the bottom frame to access the gas valve and the HI/LO
pressure regulator knob.
•
To adjust, turn the HI/LO knob counterclockwise to LO position
or clockwise to HI position, until desired flame appearance and
heat output is achieved. Reinstall bottom frame when finished.
HI/LO pressure regulator knob
Gas control knob
Figure 10.1, Millivolt Gas Control Valve