34
ELECTRICAL INFORMATION
10.3 #IPI-028 Optional Fan Kit
ATTENTION: Installation of this fan kit should be done only by
a qualified installer.
WARNING: Verify household breaker is shut off prior to working
on any electrical lines. Disconnect all electric power from
fireplace before performing any of these tasks.
This kit includes:
(2) 75 CFM fans
(4) ¼” (6mm) nuts
1. Remove the safety barrier, glass valance and access panel
2. Remove glass media and media tray.
3. Remove the control board and burner tube.
4. Insert fans through the lower opening and push to the back
of the firebox.
5. Align the mounting slots in fan brackets with the mounting
studs.
6. Secure fans with the included (4) ¼” (6 mm) nuts.
7. Plug cord into the receptacle on the IFC module housing.
8. Reinstall all components previously removed.
Figure 10.2, #iPI-028 Fan Kit
CONTROL MODULE
HOUSING