© 2020 KOSTAL Solar Electric GmbH 

 

6. 

In the KOSTAL Smart Energy Meter menu, call up the menu item „Modbus settings“> „Modbus 
RTU“ and deactivate both RS485 interfaces and confirm with Save. 

7. 

In the KOSTAL Smart Energy Meter menu, call up the menu item „Inverter“ > „Activation code“. The 
activation code, which is subject to a charge, must be purchased in advance via our web shop 

shop.kostal-solar-electric.com

8. 

Enter the previously purchased activation code for the battery function under the „Activation code“ 
item. 

xxxxxxxxxx

xxxxxxxxxx

 

P

The „Battery management“ field then appears under „Activated additional options“. 

Содержание PIKO MP plus

Страница 1: ...Textanker_Kapitel Installation guide PIKO MP plus with KOSTAL Smart Energy Meter and BYD Battery Box Premium HVS HVM ...

Страница 2: ...ender equality KOSTAL Solar Electric GmbH is aware of the importance of language with regard to the equality of women and men and always makes an effort to reflect this in the documentation Nevertheless for the sake of readability we are unable to use non gender specific terms throughout and use the masculine form instead 2020 KOSTAL Solar Electric GmbH All rights reserved by KOSTAL Solar Electric...

Страница 3: ...make all the necessary settings For all work on the devices or on the supply lines the power supply in the house the inverter and the battery must be completely de energized Take a look at the corresponding operating inst ructions for the respective devices inverter battery KOSTAL Smart Energy Meter PIKO MP plus applications The PIKO MP plus can be used as a PV inverter battery inverter or as a hy...

Страница 4: ...tery Box Premium HVS HVM battery according to the operating instructions and preconfigure it with the BYD APP 4 Set the inverters DC switch to OFF 0 5 Switch off the battery by pressing the power button min 6 sec on the front 6 Switch on the battery using the main switch on the side of the BCU 7 Set up the inverter and battery in the KOSTAL Smart Energy Meter KSEM 8 Set the inverters DC switch to ...

Страница 5: ...rgy Meter DC x BM S B M S 1 Install KOSTAL Smart Energy Meter as shown at the grid connection point 2 Establish a LAN connection from the KOSTAL Smart Energy Meter battery and inverter to the Internet 3 In this variant the KOSTAL Smart Energy Meter runs as a master and sends data to the inverter and battery Installation of PIKO MP plus for battery operation INFO Use the PIKO MP plus instruction ma...

Страница 6: ...RS485 B 87654321 1 8 8 7 5 6 4 3 2 1 A B GND ON OFF IMPORTANT Connect the battery earth BCU to the equipotential earth connection 1 Connection via RJ45 connector BYD Battery Box Premium KOSTAL Smart Energy Meter Connection Cable 1 3 RS485 A min Cat 5e Twisted pair max Ø 6 8mm max 15m 2 4 RS485 B 2 Connection via terminal strip BYD Battery Box Premium KOSTAL Smart Energy Meter Connection Cable 1 3 ...

Страница 7: ...torage mode with 1 MPP tracker DC2 for PIKO MP plus xx 2 AC or hybrid storage mode with 2 MPP trackers INFO To access the service menu press the arrow keys and on the keyboard simultaneously for a few seconds in the Service menu P After this configuration the display of the inverter lights up in red and shows the following error message because the inverter and the battery in the KOSTAL Smart Ener...

Страница 8: ...mart Energy Meter menu call up the menu item Inverter Activation code The activation code which is subject to a charge must be purchased in advance via our web shop shop kostal solar electric com 8 Enter the previously purchased activation code for the battery function under the Activation code item xxxxxxxxxx xxxxxxxxxx P The Battery management field then appears under Activated additional option...

Страница 9: ...interface of the battery Select RS485 A Min SOC state of charge Set the desired value for the minimum battery discharge depth default 5 Please note the information from the battery manufacturer BYD Battery Box Premium 5 Advanced RS485 address Enter 1 Type PIKO MP plus RS485 B RS485 A 5 1 4600 Serial interface Maximum output power Battery management Battery serial interface Advanced Min SOC state o...

Страница 10: ...a of the overall system can be called up via the KOSTAL Solar Portal or the KOSTAL Solar App To do this the inverter and the KOSTAL Smart Energy Meter must be configured to send data to the KOSTAL Solar Portal 1 The transfer of data yield data is activated in the PIKO MP plus as follows 2 The transfer of data house consumption self consumption and battery values is activated in the KOSTAL Smart En...

Страница 11: ... PIKO MP plus you will find the necessary data article number serial number on the type label With the KOSTAL Smart Energy Meter please use the data from the internal web server of the KOSTAL Smart Energy Meter which can be found under Inverters Solar Portal KOSTAL Solar Portal www piko solar portal com PIKO MP plus KSEM xxxxxxxxxx xxxxxxxx xxxxxx xxxx H Commissioning of the entire system has now ...

Страница 12: ...ic Hellas Ε Π Ε 47 Steliou Kazantzidi st P O Box 60080 1st building 2nd entrance 55535 Pilea Thessaloniki Ελλάδα Τηλέφωνο 30 2310 477 550 Φαξ 30 2310 477 551 KOSTAL Solar Electric Italia Srl Via Genova 57 10098 Rivoli TO Italia Telefono 39 011 97 82 420 Fax 39 011 97 82 432 KOSTAL Solar Electric Turkey Mahmutbey Mah Taşocağı Yolu No 3 B Blok Ağaoğlu My Office212 Kat 16 Ofis No 269 Bağcılar İstanbu...

Отзывы: