Acces s ing data v ia PRO F I BUS
Operating manual for PROFIBUS fieldbus | DOC01185928-0008 | 2016-12 | V1.8 DE
47
PROFIBUS
INVEOR parameter
Slot
Index
Parameter
Number*
Accepted
Name in German
Minimum
Maximum
Unit
2
136
392
34.226
2: Always
PMSM start-up current
5
1000
%
2
143
399
34.227
1: Ready
PMSM init. time
0
100
s
2
140
396
34.228
1: Ready
PMSM start-up
procedure
0
1
2
141
397
34.229
1: Ready
PMSM start-up ramp
0.1
1000
s
2
142
398
34.230
1: Ready
Start-up frequency P
5
400
Hz
2
120
376
35.080
2: Always
Brake chopper
0
1
Tab.: 8 Parameter