Connection to the central heating system

Cylinder must be fitted to the central heating system 

by pipe unions 3/4″. A cut-off valves must be installed 

before the pipe unions. A flow rate of heating water must 

be high enough to maximise cylinder’s efficiency (see 

technical data table). It concerns the forced circulation 

installation (with a central heating water pump).

Connection to the water system

Connection to the water system must be performed according to binding norms of 

hydraulic installation. The cylinder is a pressure appliance designed for connection to 

the water supply system where the water pressure doesn’t exceed 0,6 MPa. If the water 

pressure exceeds 0,6 MPa, the pressure reducing valve before cylinder must be fitted.

Please follow the water connection instructions below:

install the T-connection with 6 bar safety valve (e.g. ZB-4)  to the fitting of cold 

water  inlet  [ZW]. It’s  forbidden  to  install  a  cut-off valve  (or  any  flow  reducer) 

between tank and the safety valve and on its outlet. The safety valve must be 

installed in such a place as to quickly let you notice the outgoing water,

install the cylinder equipped with the safety valve to the water system,

install the cut-off valve on cold water supply pipe.

Hot water outlet should be led to the connection 3/4″ in the upper part of the cylinder.

Every  cylinder  is  equipped  with  connection  3/4″  intended  for  its  installation  to  the 

DHW circulation. 