Connection to the water system must be performed according to binding norms of 

hydraulic installation. The cylinder is a pressure appliance designed for connection 

to the water supply system where the water pressure doesn’t exceed 0,6 MPa. If the 

water pressure exceeds 0,6 MPa, the pressure reducing valve before cylinder must 

be fitted. Please follow the water connection instructions below:

install the T-connection with 6 bar safety valve (e.g. ZB-4) and the drain valve to 

the fitting of cold water inlet [ZW]. It’s forbidden to install a cut-off valve (or any 

flow reducer) between tank and the safety valve and on its outlet. The safety 

valve must be installed in such a place as to quickly let you notice the outgoing 

water,

install the cylinder equipped with the safety valve to the water system,

install a cut-off valve on the cold water inlet.

Hot water outlet should be led to the connection in the upper part of the cylinder.

Every  cylinder  is  equipped  with  connection  3/4″  intended  for  its  installation  to  the 

DHW circulation. 

Connection to the water system

ZG

PG

Ø 460

270

G1

G1

A

226

702

G1/2

G3/4

526

778

6

1

2

3

5

7

3

CW

ZW

8

4

[1]  -  anode’s blank

[2]  -  magnesium anode

[3]  -  thermal insulation

[4]  -  hanger

[5]  -  thermometer

[6]  -  sensor pipe 

[7]  -  heating coil

[8]  -  immersion heater connection (cork 1½

)

ZW  -  cold water

CW  -  hot water

C  -  circulation

ZG  -  heating medium supply

PG1 -  heating medium return

A  -  dimension  specified  in  the  diagram 

Technical data