In case the appliance does not heat water, check for possible reasons:

-  a failure of the mains supplies (e.g. fuses),
-  insufficient flow through the heater (e.g. dirty  filter, incorrect setting of the flow regulating valve) - refer to 

"Flow regulation".

The guarantee does not cover the above repairs.
If there is a fault in the appliance (the heater does not work and all the above reasons do not occur), contact  

the nearest authorised service.

EPJ -  water heater 

 

 - 1 piece,

Tap set 

 

 - 2 piece,

Gasket 

 

 - 1 piece,

Spanner for  regulating the flow 

 

 - 1 piece,

Screw 

 

 - 1 piece,

Sleeve 

 

 - 1 piece,   

Set contents

Faults 

If  the  inseparable  supply  cord 

will become damage, it should 

be replaced at the manufacturer 

or in special repair shop or by 

a  qualified  person  in  order  to 

avoid all risks.

This appliance is not intended 

for  use  by  persons  (including 

children) with reduced physical, 

sensory or mental capabilities or 

lack of experience and knowl-

edge,  unless  they  have  been 

given supervision or instruction 

concerning use of the appliance 

by a person responsible for their 

safety.

Children should be supervised 

to ensure that they do not play 

with the appliance.

Содержание Optimus EPJ-3

Страница 1: ......

Страница 2: ...n and operating instructions carefully to ensure the long life and reliable operation of this appliance Kospel S A may make minor changes if necessary in the appliance that will not be shown in the op...

Страница 3: ...uts the appliance The heater features tubular heating coils that assure maximum safety materials resistant to corrosion and chemically inactive with water copper brass stainless steel plastic This app...

Страница 4: ...drilled hole 6 Disconnect the heater from the tap body 7 Drill a hole of 35 depth and 6mm diameter at the marked point 8 Connect the tap body 19 using nuts 26 with a gasket 13 and the filter 12 to th...

Страница 5: ...valve 4 set optimum flow check if the temperature is comfortable for you using the spanner 25 close water flow using the tap take the spanner 25 out of the regulation valve 4 Picture 3 Regulation 4 re...

Страница 6: ...7 Open cold water pipe on water supply check connections for leaks 8 Vent the installation The filter should be cleaned after you repair the water sys tem if a lot of effluent appears or after a year...

Страница 7: ...he construction of EPJ 4 4 5 5 in the diagram No 8 Safety temperature limiter 3 pro tects against overheating After the limiter goes off you can turn the hot water tap on but heating will not start Re...

Страница 8: ...sure switch 3 safety temperature limiter 4 regulating valve 6 inlet cold water 7 outlet hot water 24 heat on indicator 8 Picture 9 EPJ 4 4 EPJ 5 5 wiring diagram E1 heating box 1 BV1 differential pres...

Страница 9: ...ece Tap set 2 piece Gasket 1 piece Spanner for regulating the flow 1 piece Screw 1 piece Sleeve 1 piece Set contents Faults If the inseparable supply cord will become damage it should be replaced at t...

Страница 10: ...10 Installation and operation instruction EPJ...

Страница 11: ......

Страница 12: ......

Отзывы: