17.  Plastic pipes at the inlet and outlet may be used to connect the water heater, and 

in the case of the outlet pipes, their strength shall be at least 20 bar at 70°C.

18.  Make sure that the heater is not emptied of water, which may occur if there is no 

water in the supply network.

19.  Failure to install the magnetic filter on water supply pipe can cause unit damage.

20.  Lime scale built-up on heater’s elements may limit water flow and lead to heater’s 

damage. Such damages are not subjected to warranty rights. Water heater and 

sanitary  fittings  should  be  periodically  descaled,  whereas,  frequency  of  this 

process should be adjusted to water hardness in given installation. Lime scale 

built-up may be partially limited by usage of magnetic descalers installed on the 

cold water inlet pipe. 

21.  Appropriate precaution must be taken when using hot water. Temperature of water 

over 40°C may cause hot feeling and can be dangerous for children, whereas,  

temperature above 50°C may lead to first degree burn (especially amongst small  

children).

Содержание EKP.LN2M

Страница 1: ...EKP LN2M Electric Central Heating Flow Boiler Assembly and operating instructions...

Страница 2: ...mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children sh...

Страница 3: ...sional installer 9 All installation work must be performed when the power and water supply is turned off 10 Electric installation should be equipped with residual current protective devices and other...

Страница 4: ...limit water flow and lead to heater s damage Such damages are not subjected to warranty rights Water heater and sanitary fittings should be periodically descaled whereas frequency of this process shou...

Страница 5: ...m 5 Vent the central heating system 6 Open the cold water supply valve and check the tightness of the water connections 7 Vent the DHW system according to DHW system venting section 8 Connect the devi...

Страница 6: ...r hot water control control valve valve Boiler connection to the CH system ZK cut off valve ZT thermostatic valve ZP passage valve F magnetic filter G radiator RT room temperature thermostat Tos outsi...

Страница 7: ...contact gets opened heating will be turned off and the pump will be stopped If the device works as a secondary heat source the master boiler stops the heating by opening the MA contact WE 027 outside...

Страница 8: ...cut off valve on the outlet let the boiler with the pump on run for 15 30 s open the cut off valve 5 Switch the boiler off press and hold button for 3 seconds 6 Set the pump at automatic mode see sec...

Страница 9: ...switch off f 4 25 f 0 weather compensation switched off manual regulation of installation s temperature heating curve offset o 9 C 9 C outside temperature of CH switch off setting outside temperature...

Страница 10: ...pressure indicator flushing pressure sensor in CH installation active 1 inactive 0 sensor should be deactivated in open type installations maximum temperature of CH installation number of active heat...

Страница 11: ...of room termostat and heating activity for central heating G indicator of pump and flow activity H indicator of weather compensation controller I inlet temperature indicator J outlet temperature indi...

Страница 12: ...L value of water flowing through the heater indicators L and B current power consumed by the water heater indicators C and L CH medium temperature adjustment indicators K and D indicator H is on when...

Страница 13: ...r temperature setting indicators L and D Using buttons or you can change the domestic water setting value domestic water temperature at the inlet indicators L I and D domestic water temperature at the...

Страница 14: ...eating on boiler s CH mode green desired temperature has been reached boiler co operates with DHW cylinder icon in red temp in CH system is lower than required but the required room temperature has be...

Страница 15: ...ion and clean the filter failure of pump s power supply contact authorised service failure of pump or flow sensor contact authorised service F indicator is off in winter mode room thermostat indicates...

Страница 16: ...ng wires section mm2 3 x 25 5 x 25 The maximum allowed network impedance 0 24 0 22 0 27 0 13 Water heater Efficiency at t 30 C and water pressure at 0 4 MPa l min 5 3 6 3 8 7 11 6 Pressure in the wate...

Страница 17: ...cting wires section mm2 3 x 25 5 x 25 The maximum allowed network impedance 0 24 0 22 0 27 0 13 Water heater Efficiency at t 30 C and water pressure at 0 4 MPa l min 4 9 5 8 7 8 10 3 Pressure in the w...

Страница 18: ...MPa 0 3 3 bar Min pressure MPa 0 05 0 5 bar Outlet temperature C 20 85 Max temperature C 100 Dimensions height x width x depth mm 690 x 451 x 258 Weight kg 19 Boiler s connections 22mm Expansion vess...

Страница 19: ...equipment for recycling Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more...

Страница 20: ...KOSPEL Sp z o o 75 136 Koszalin ul Olchowa 1 Poland tel 48 94 31 70 565 serwis kospel pl www kospel pl Made in Poland...

Отзывы: