16
8:38 THU 24,08,2017
PARTY/HOLIDAY/MANUAL
PARTY / HOLIDAY / MANUAL
Fast changing of the workflow algorithm
according to needs.
● PARTY:
setting mode duration (from 1 to 24 hours
or until cancelled)
● HOLIDAYS:
setting mode duration (from 1 to 60 days or until cancelled).
● MANUAL:
Set the room temperature by the system control - until cancelled.
● TURBO:
turning on the place’s heating up with max parameters - until reaching the set
room temperature.
* If any of the above modes are ON, then after entering ‘Party / Holiday / Manual’ there is a possibility
to turn it off, and in case of setting the manual mode, it is also possible to change the set temperature.
* Mode symbol is indicated on the main function screen.
8:38 THU 24,08,2017
SERVICE/CONFIGURATION
SERVICE / CONFIGURATION
Preview of parameters:
preview of input and output signals of the boiler.
Configuration:
adaptation of the boiler to the
heating system in the facility.
* (Changes in the configuration menu are possible after entering an access code. When prompted
for an access code, turn the navigation dial to the required code and confirm the code by pressing
the dial. If you want to retract from the code request screen, hold the navigation dial or wait until
automatic return to main function screen.)
● CENTRAL HEATING:
-
NO OF HEATING: selection of the heating curve.
-
HEATING CURVE: shift of the heating curve.
-
MAX POWER TEMP: maximal central heating system temperature
-
POWER TEMP MANUAL: temperature in the installation while operating with
constant parameters and in emergency conditions.
-
REGULATION: per curve -> the temperature in the installation is calculated on
the basis of the outside temperature taking into account heating curve settings
/ Constant parameters - the temperature in the installation is equal to power
temperature manual.