24
6-12 KT-1903NA adjustment method
1. B+ voltage adjustment method
1) Measuring terminal
: D114 CATHODE side
2) Adjusting V/R
: V/R101
3) Adjusting voltage
: 54
±
0.2V
4) Measuring condition
: AC 120 V, 60 Hz ,CROSS HATCH PATTERN
5) Other voltage
: 6.2
±
0.1V 122
±
0.5V
2. SCREEN voltage adjustment method
1) Measuring terminal
: C933 (SCREEN)
2) Adjusting V/R
: F.B.T SCREEN V/R
3) Adjusting voltage
: 550
±
5V
4) Measuring condition
: CROSS HATCH PATTERN
3. HIGH VOLTAGE adjustment method
1) Measuring terminal
: CRT ANODE
2) Adjusting voltage
: 23.4 Kv
±
300 V
3) Measuring condition
: CROSS HATCH PATTERN
Screen size : at the full scan (horizontal frequency :31.5 Khz)
4. CONTRAST adjustment method
1) Measuring terminal
: center of screen
2) Adjusting V/R
: V/R402,V/R406,V/R407
3) Measuring condition
: SCREEN voltage : 550
±
5V
VIDEO input voltage : 0.7V
Screen brightness : 15F/L ~ 55F/L
4) Adjusting method :To supply Window pattern by operation of SIGNAL SOURCE
To adjust V/R 402 for brightness into 55F/L at the Max of V/R 406
To adjust V/R 407 for brightness into 15F/L
KORTEK Corporation