EMX-1/ESX-1 Tube Calibration
›ῐ
Connect the stereo plug of the cable (see fig.) to PHONES and the monaural plug to
INPUT.
2. While pressing ERACE and STEP EDIT, turn the power on. “Valv Wup” is
indicated as stand-by for pre-heating, and also the waiting time is indicated.
Set up the volume knob and switches as follows:
MASTER VOLUME : MAX
TUBE GAIN : MIN
AUDIO IN LEVEL : MAX
MIC/LINE : MIC
3. “Ajst (L)” and a 4 digits figure are indicated in the LCD. If the value is leas than
0010, the test is O.K.. Press the 16 knob at the right bottom. If the value is over it, it is
required to adjust the valve. Adjust the variable resistors which correspond to the
channels referring to the photo below.