![Korenix JetNet 3710G Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/korenix/jetnet-3710g/jetnet-3710g_user-manual_1997840014.webp)
Korenix
JetNet 3810G(f)/ 3806G/ 3710G
13
2.4 Wiring Earth Ground
To ensure the system will not be damaged by noise or electric shock, we suggest
making a direct connection between the JetNet 3810G(f)/3806G/ 3710G
and earth
ground to avoid system damage. (Please refer to the upside photo)
1. On the bottom of the JetNet 3810G(f)/3806G/ 3710G, there is one earth ground
screw.
2. Loosen the earth ground screw with a screwdriver
3. Tighten the screw after the earth ground wire is connected.
2.5 DIP Switches
10-Pin Dip switches are located on the bottom panel of JetNet 3810G(f)/ 3710G for
configuration purpose (6-Pin for JetNet 3806G). They are used to configure Port
Alarm to corresponding TX ports.
DIP Switch number
Status
Description
On
To enable GbE port break alarm at this port
DIP 1~2
JetNet 3810G(f)/3710G/
3806G
Off
To disable GbE port break alarm at this port
(Default)
On
To enable PoE port break alarm at this port
JetNet 3810G(f)/3710G:
DIP 3~10
JetNet 3806G:
DIP 3~6
Off
To disable PoE port break alarm at this port
(Default)
Note:
DIP Switch number mapping to corresponding PoE port & GbE port as follow:
DIP Switch #
3
4
5
6
7
8
9
10
PoE port
1
2
3
4
5
6
7
8
DIP Switch #
1
2
GbE port
2
1