![Korenix JetNet 3705-24V Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/korenix/jetnet-3705-24v/jetnet-3705-24v_user-manual_1997836011.webp)
JetNet 3705-24V 5-port Industrial Fast Ethernet Power over Ethernet Switch
8
Wiring the Power Inputs
Please follow the steps below to wire the power cord which from the other compliant
external DC power supplier.
1. Insert
the
positive
and negative wires into the
PWR1 (V1+, V1-)
and
PWR2 (V2+,
V1-)
contacts on the terminal block connector as shown in
Figure-6
.
Figure-6: Terminal Block Front View for Power1 & Power2 Contact
2. Tighten the wire-clamp screws which as shown in the
Figure-7
for preventing the
wires from loosing.
Figure-7: Terminal Block Top View
Note
¾
Use Copper Conductors Only, 60/75
°
C, Tighten to 5 lb in
¾
The wire gauge for the terminal block should be in the range
between 12~ 24 AWG.
¾
Using UL certified AC/DC switching power as power
source. The output power should not less than 70W.
V2-
V2+
V1-