JetNet 3705-24V
5-port Industrial Fast Ethernet PoE Switch
User Manual
Revision V1.0
Страница 1: ...JetNet 3705 24V 5 port Industrial Fast Ethernet PoE Switch User Manual Revision V1 0...
Страница 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...
Страница 3: ...Front Panel 4 Top View 4 LED Indicators 5 Ports 6 Cabling 7 Wiring the Power Inputs 8 Wiring the Fault Alarm Contact 9 Mounting Installation 10 DIN Rail Mounting 10 Wall Mounting 11 Hardware Installat...
Страница 4: ...4 ports 15 4w power consumption With the rugged Aluminum alloy housing the JetNet 3705 24V survived under 25 C 60 C environment temperature give your Power over Ethernet application best reliability...
Страница 5: ...checklist JetNet 3705 24V User manual Removable Terminal Block installed on the device Wall mount Kit 2 wall mount bracket with screws Compare the contents of the industrial switch with the standard...
Страница 6: ...ndustrial switch s hardware specs ports cabling information and wiring installation will be described Physical Dimension JetNet 3705 24V dimensions W x D x H is 48 6mm x 95mm x 140mm the detail dimens...
Страница 7: ...Front Panel of the PoE Injectors Industrial Switch Top View The top view of the JetNet 3705 24V has one terminal block connector of two DC power inputs and Relay circuit contact Please refer to Figur...
Страница 8: ...er input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 has failed P Fail Red Off Power input 1 and 2 are both functional or no power inputs On The port is supplying power to...
Страница 9: ...on this industrial switch supports automatic MDI MDI X operation users can use straight through cables See figures below for all network connections to PCs or Servers or to other switches hubs In stra...
Страница 10: ...witch Switch 3 TD 3 RD 6 TD 6 RD 1 RD 1 TD 2 RD 2 TD Figure 5 Crossover Cable Schematic Cabling Twisted pair segments can be connected with unshielded twisted pair UTP or shielded twisted pair STP cab...
Страница 11: ...on the terminal block connector as shown in Figure 6 Figure 6 Terminal Block Front View for Power1 Power2 Contact 2 Tighten the wire clamp screws which as shown in the Figure 7 for preventing the wire...
Страница 12: ...e refer to Figure 8 for the fault alarm contact and Figure 9 shows the application example for the fault alarm operation Figure 8 Terminal Block Front View for Fault Alarm Contact Figure 9 Fault Alarm...
Страница 13: ...on line in the factory If the bracket is not screwed on the switch please refer to Figure 10 to screw it on the switch Follow the steps below to hang the industrial switch Figure 10 Rear side of the P...
Страница 14: ...teps above Wall Mounting Please refer to Figure 12 and follow the steps below to mount the industrial switch with wall mount bracket and the detail dimension of the bracket as Figure 13 1 Remove the D...
Страница 15: ...12 Figure 12 Wall Mount Bracket Installation Figure 13 Wall Mount Bracket Dimension...
Страница 16: ...IN Rail or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the...
Страница 17: ...Switch 14 Network Application This segment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the Figure 14 b...
Страница 18: ...Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the Switch can be easily monitored thro...
Страница 19: ...880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX Fast Ethernet port MAC Address 2K MAC address table Connector 10 100TX 5 x RJ 45 Power P Fail 1 x 6 poles Removable Terminal Block PoE Pin...
Страница 20: ...umption 62 5 Watts 48V 67 Watts 24V Full load with PoE function Installation DIN Rail mounting Wall mounting Operating Temp 25o C to 60o C standard model Operating Humidity 5 to 95 Non condensing Stor...
Страница 21: ...strategy focuses on establishing and developing trustworthy relationships with value added distributors and channel partners and assisting OEM distributors to promote their own brands Korenix supplie...