Korenix
JetNet 3508-LVDC/ JetNet 3508G-LVDC
10
1.
Insert the positive and negative wires of your DC supply into the V+ and V-
contacts of the M12 A-Code Female connector. The acceptable wire range is 12 to 24
AWG.
2.4 Wiring Earth Ground
To ensure the system will not be damaged by noise or electric shock, we suggest
making a direct connection between the JetNet 3508-LVDC/ JetNet3508G-LVDC
and
earth ground to avoid system damage in below photo.
1. On the right side of bottom of the JetNet 3508-LVDC / JetNet3508G- LVDC, there
is one earth ground screw.
2. Loosen the earth ground screw with a screwdriver
3. Tighten the screw after the earth ground wire is connected.
2.5 Rotary Switches (Ignition Function)
4-Pin rotary switch is one of components to trigger delay off into standby mode
function, the detail shows in table 1, how does ignition function work. It is showed in
diagram 1.