1.The above cooling capacity are calculated at ambient temperature DB 30

    WB 25.4

.

2.Our company has quick technical improvement. There will be no prior 
   notice for any change of technical data. Please read the nameplate on the 
   air conditioner.
3. The working temperature range of the air conditioner is 18~35

.

          

Cleaning Air Filter 

 If the air filter is covered by dust, the cooling effect will be decreased.
 Please clean the air filter every two weeks. 

1. Turn off the air conditioner and cut off  the power supply. 
2. Pull out the filter cover and remove the 
    filter from cover.
3. Wash air filter in warm soap water. 
    Do not put air filter in the dishwasher or 
    use any chemical cleaners. And dry filter
    completely before replacing.
4. Attach the air filter to the filter cover 
   using the attachment hooks on the inner 
   surface of the cover. Put the filter cover
   back to its place.

Maintenance 

Your new air conditioner is designed to give you many years of dependable service. 
This section tells you how to clean and care for your air conditioner properly. 

Window kit installation

 

Your window kit has been design to fit most standard vertical and horizontal 
window applications. However, it may be necessary for you to improvise or 
modify some aspects of the installation procedure for certain types of window. 
Please refer to fig. A &fig. B for minimum and maximum window openings.  

Vertical 
window 

Window slide kit 
minimum:67.5cm 
maximum:125cm 

Horizontal window 

Window slide kit 
minimum:67.5cm 
maximum:125cm 

Fig. A 

Fig. B 

9

2

Fig. C 

Note:The bolt and nut are used to fix  window fixing board.

Nut

Bolt

Technical Specifications  

Model

 

Cooling capacity (Btu/h)

9000

AM-H09A4/BR

3

Air flow (m /h)

Rated input 
current (A)

Rated input 

 

power

(W)

Power supply 

Refrigerant 

Weight (kg)

Noise dB(A)

Dimension(mm)

2

Suitable room area (m )

330

4.5

220-240V~/50Hz

R407c

37

52

10-15

829

491

420

F3.15AL (250V  3.15A)

Type of the fuse

Electric heating

 (W)

Cooling

Heating

12000

KMA1-12GRC

330

4.5

14-20

Cooling

Heating

1050

1050

2000

3000

7.95

7.95

1750

1750

Содержание KMA1-12GRC

Страница 1: ...PORTABLE AIR CONDITIONER INSTALLATION OPERATIONS MANUAL FOR FUTURE REFERENCE KMA1 12GRC KOREL AIR CONDITIONING...

Страница 2: ...Wiring diagram HEATER ONLYTHE UNIT WITH HEATING MODE HAS HEATER Cooling Heating 12...

Страница 3: ...ambient temperature Clean the airfilter Remove the obstruction Allow additional time to remove stored heat from walls ceiling floor and furniture Reconfirm the required cooling capacity with yourdeal...

Страница 4: ...ons below to see if you can solve your problem without outside help Causes Solutions The power switch is released Power supply failure The fuse is burnt It doesn t reach the set time for start up Swit...

Страница 5: ...er is designed to give you many years of dependable service This section tells you how to clean and care for your air conditioner properly Window kit installation Your window kit has been design to fi...

Страница 6: ...itioner According fix it with unit correspondingly then turn right Push it downwards make sure thatit is fixed thoroughly 2 Put theother side ofthe duct to adaptor 3 Put the adapor to a nearby window...

Страница 7: ...let matching with the plug of the air conditioner If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 7 4...

Страница 8: ...ain to stop 5 6 Operation Failure to follow the below precaution could result in electrical shock fire or personal injury 1 The plug must be plugged into an outlet that is properly installed and groun...

Отзывы: