22
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
4.6.3
Power supply " Dual"
The supply voltage for the axis controllers is supplied by the supply unit ServoOne CM-P
via the busbars (DC link). This voltage, also called the DC link voltage, is between
565 V DC and 678 V DC, depending on the mains supply to the SO CM-P (400 V AC
and 480 V AC).
The expansion module is used to protect, monitor and adapt the smaller cable cross-
section (DC link = lower current carrying capacity) of the axis controllers SO CM BG1+2
to the larger cable cross-section (DC link = higher current carrying capacity) of the axis
controllers SO CM BG3+4.
Figure
Key
24 V DC Netzteil
(Power Supply)
2.
DC-Link +
DC-Link -
3.
4.
1.
X2
5.
6.
1.
DC link jumper (large cross-section)
2.
Controller MotionOne CM
3.
Supply unit SO CM-P BG3
4.
Axis controller SO CM BG3
5.
Expansion module SO CM-E
6.
Axis controller SO CM BG1
Note:
The DC link busbar fittings are to be tightened to a
torque of 2.1 Nm. Jumpers and screws are included in
the scope of supply and are in the accessories pack.
Figure 4.6 Busbars, power supply (DC link)
4.6.2
24 V control supply, "Dual End" model
Figure
Key
5.
6.
X2
4.
4. "24 V control supply from the 1st
expansion module of type "Dual" terminal X2
5. SO CM-E expansion module "Dual End"
6. SO CM axis controller BG1
NOTE:
The 24 V DC busbar
fittings are to be tightened
to a torque of 2.1 Nm.
For details and an overview, see Table 4.5
Figure 4.5 Busbars, 24 V control supply (type "Dual End")
Содержание LTI MOTION ServoOne CM
Страница 1: ...Expansion module Compact multi axis system ServoOne CM ServoOne CM Operation Manual...
Страница 12: ...12 Safety Operation Manual Expansion Module SO CM E 1800 202B 0 01 Date 02 2019 2 8 Declaration of conformity...
Страница 30: ...30 Operation Manual Expansion Module SO CM E 1800 202B 0 01 Date 02 2019...
Страница 37: ...37 Operation Manual Expansion Module SO CM E 1800 202B 0 01 Date 02 2019...