BEAT THE HEAT!

KoolTray II

- 19” width fan

cooling units. Available in 1, 2
and 3 row configurations.
Custom/Special units available.

Pennington, NJ

Ventura, CA

Tel: (609) 466-3400

Tel: (805) 642-8521

Fax: (609) 466-1114

Fax: (805) 658-2901

Free

comprehensive

Design

Guide / Catalog

for selecting

the proper Air Conditioner,
Heat Exchanger, Blower or
Fan.

NEW!

Advantage Air Conditioners and Heat Exchangers -

Ready

f

or Indoor or Outdoor Installation Right Out of

the Box! With rounded edges; no visible hardware
and a textured baked powder finish to blend easily
with contemporary enclosure designs.  Integral
weather protection eliminates unsightly weather
hoods and a patented sealing system maintains
both a NEMA 12 and a NEMA 3R interface with the
enclosure.

Visit us online at:

www.kooltronic.com

E-Mail: [email protected]

Integrity NEMA 4/4X Air Conditioners and
Heat Exchangers

- Only by Kooltronic! Designed

for applications that require washdown or are
subject to outdoor conditions. 

Air Conditioners

from 1,000 to 10,000 BTU/H.

Heat Exchangers 

up to 65 W/°F.

Basic and Packaged Fans -

Compact designs and
packaged units. Capacities
from 200 to 1310 cfm.

FREE!

Basic and Packaged Blowers -

Basic units and packaged units
for 19” EIA Rack; w/Grille, Filter
and Guards. Capacities from
130 cfm to 1250 cfm.

Heat Exchangers -

Air-to-Air and Water-to-Air
models in a variety of
sizes with capacities up to
91 Watts/ºF

.

Motorized Impellers -

Delivers high CFM rates in a
minimum amount of space.

NEW!

Air Conditioners -

Traditional, TrimLine, Mini,
Rack-Mount and Top-Mount
models. Available in
capacities from 1,000 to
30,000 BTU/H.

Содержание K2NA4C3P21R

Страница 1: ...UTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FA...

Страница 2: ...ntroduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronics enc...

Страница 3: ...a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating t...

Страница 4: ...ESSURE P S I G LOW HIGH MAX FUSE SIZE SERVICE AIR FILTERS REGULARLY ALLOW 5 MIN BEFORE RESTARTING AFTER SHUTDOWN UNAUTHORIZED SERVICE OR MODIFICATION VIOLATES WARRANTY ALL MOTORS ARE THERMALLY PROTECT...

Страница 5: ...leased to the ambient air by the condenser impeller The heat removed through the evaporator coil is transferred by the compressed refrigerant to the condenser coil Ambient air is then passed through t...

Страница 6: ...test for proper operation This will verify the shipping integrity of the system Please follow the steps below prior to installation CAUTION 1 The unit must sit in an upright position at a minimum roo...

Страница 7: ...O THE OUTSIDE WALL OF THE CUSTOMER S ENCLOSURE BEFORE INSTALLING A C UNIT NOTE ENCLOSURE WALL TYP 3 PLACES 1 4 NUT CUSTOMER S ENCLOSURE TYP 3 PLACES BOLT 1 4 X 1 1 4 RUBBER WASHER MOUNTING PLATE WITH...

Страница 8: ...erence only and are subject to change 6 312 7 9 DIA HOLES 7 94 201 6 TYP 1 25 31 7 20 09 510 2 TYP 7 00 177 8 1 75 44 4 7 00 177 8 2 03 51 5 TYP 2 64 67 0 48 12 1 4 75 120 6 TYP 12 01 305 0 21 19 538...

Страница 9: ...21R5 Part Part Number Part Number Part Number Compressor 0665 101 0665 107 0665 110 Compressor Impeller 0194 14 0194 15 0194 15 Condenser Impeller Capacitor 0452 06 0452 73 0452 73 Evaporator Fan 0265...

Страница 10: ...RMAL CUTOUT T STAT 115 V 230 V TO CUSTOMER ALARM SYSTEM OPTIONAL TERMINAL BLOCK COOLING EFFECT DETECTOR BK T STAT SHORT CYCLE TIMER OPTIONAL SHORT CYCLE PROTECTOR OPTIONAL HEATER SPEED CONTROLLER COND...

Страница 11: ...ld setting and the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service...

Страница 12: ...e air conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refrigerant leaks during and after manufacture It is...

Страница 13: ...lay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Application Failed Evaporator Blowe...

Страница 14: ...14 This page intentionally left blank...

Страница 15: ...is requested Original customer Purchase Order number and date Date product was received by customer Number of parts to be returned Product description model and serial number Reason for return Action...

Страница 16: ...and a NEMA 3R interface with the enclosure Visit us online at www kooltronic com E Mail sales kooltronic com Integrity NEMA 4 4X Air Conditioners and Heat Exchangers Only by Kooltronic Designed for a...

Отзывы: